Expansion
I/O
tower
(FC
5077)
(see
for
part
number)
–
System
unit
expansion
(FC
507x)
(see
for
part
number)
–
Storage
expansion
tower
(FC
508x)
-
see
the
next
FRU
in
the
SRC
list.
This
ends
the
procedure.
10.
Is
the
SRC
1xxx
6x58?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Power
regulator
3
is
the
failing
item.
The
following
list
shows
the
possible
failing
items:
–
Expansion
I/O
tower
(FC
5077)
(see
for
part
number)
–
System
unit
expansion
(FC
507x)
-
no
regulator
installed,
see
the
next
FRU
in
the
SRC
list.
–
Storage
expansion
tower
(FC
508x)
-
no
regulator
installed,
see
the
next
FRU
in
the
SRC
list.
This
ends
the
procedure.
11.
Is
the
SRC
1xxx
7201,
7202,
7203,
or
7401?
v
No
:
Continue
with
the
next
step.
v
Yes
:
One
of
the
power
regulators
is
the
failing
item.
The
following
list
shows
the
possible
failing
items:
–
Expansion
I/O
tower
(FC
5077)
(see
for
part
number)
–
System
unit
expansion
(FC
507x)
(see
for
part
number)
–
Storage
expansion
tower
(FC
508x)
(see
for
part
number)
–
Battery
charger
(see
symbolic
FRU
This
ends
the
procedure.
12.
Is
the
SRC
1xxx
B101
or
B102?
v
No
:
Continue
with
the
next
step.
v
Yes
:
If
the
system
can
be
powered
on
with
this
SRC,
perform
symbolic
FRU
and
then
continue.
One
of
the
power
regulators
is
the
failing
item.
The
following
list
shows
the
possible
failing
items.
–
System
unit
-
programmable
regulator
R01,
R02,
R04-R11,
R20
(see
for
part
number)
–
System
unit
-
memory
control
regulator
R03
(see
for
part
number)
–
Expansion
I/O
tower
(FC
5077)
(see
for
part
number)
–
System
unit
expansion
(FC
507x)
(see
for
part
number)
–
Storage
expansion
tower
(FC
508x)
(see
for
part
number)
–
Battery
charger
(see
symbolic
FRU
This
ends
the
procedure.
13.
Is
the
SRC
1xxx
B201
or
B202?
v
No
:
Go
to
This
ends
the
procedure.
v
Yes
:
If
the
system
can
be
powered
on
with
this
SRC,
perform
symbolic
FRU
and
then
continue.
The
battery
unit
is
reporting
an
over-current.
The
following
list
shows
the
possible
failing
items.
–
System
unit
-
programmable
regulator
R01,
R02,
R04-R11,
R20
(see
for
part
number)
–
System
unit
-
memory
control
regulator
R03
(see
for
part
number)
–
Battery
charger
-
part
21H7060
(see
symbolic
FRU
This
ends
the
procedure.
430
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation
Содержание iSeries Series
Страница 2: ......
Страница 504: ...492 iSeries iSeries Server 270 800 810 820 825 830 840 870 890 SB2 and SB3 Hardware Problem Analysis and Isolation...
Страница 508: ...496 iSeries iSeries Server 270 800 810 820 825 830 840 870 890 SB2 and SB3 Hardware Problem Analysis and Isolation...
Страница 511: ......
Страница 512: ...Printed in USA SY44 5914 01...