v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
CRUs
and
which
components
are
FRUs.
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
166-411-001
System
Management:
Failed
(BMC
indicates
failure
in
I2C
bus
test)
Shutdown
and
remove
the
blade
server
from
the
BladeCenter
unit,
wait
30
seconds;
then,
reinstall
the
blade
server
in
the
BladeCenter
unit
and
restart
it.
If
problem
persists,
perform
the
following
tasks
in
the
order
shown,
restarting
the
blade
server
each
time:
1.
Remove
the
blade
server
from
the
BladeCenter
unit;
then,
remove
the
card
from
the
I/O
expansion
card
slot
B
in
the
Blade
Storage
Expansion
Unit
3.
Reinstall
the
blade
server
in
the
BladeCenter
unit
and
restart
it.
2.
Update
the
BMC
firmware.
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
166-406-001
BMC
indicates
failure
in
I2C
bus
test.
1.
Remove
the
blade
server
from
the
BladeCenter
unit,
wait
30
seconds,
reseat
it
in
the
BladeCenter
unit,
and
run
the
test
again.
2.
Update
the
BMC
firmware
(see
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
166-407-001
System
Management:
Failed.
BMC
indicates
failure
in
I2C
bus
test.
1.
Remove
the
blade
server
from
the
BladeCenter
unit,
wait
30
seconds,
reseat
it
in
the
BladeCenter
unit,
and
run
the
test
again.
2.
Update
the
BMC
firmware
(see
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
166-nnn-001
System
Management:
Failed.
BMC
indicates
failure
in
self
test.
Note:
v
nnn
=
300
to
320
v
nnn
=
400
to
420,
excluding
406
and
407
1.
Remove
the
blade
server
from
the
BladeCenter
unit,
wait
30
seconds,
reseat
it
in
the
BladeCenter
unit,
and
run
the
test
again.
2.
Update
the
BMC
firmware
(see
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
180-xxx-000
Diagnostics
LED
failure.
Run
the
LED
test
in
the
diagnostics
program.
180-xxx-001
Failed
front
LED
panel
test.
1.
Reseat
the
control-panel
connector.
2.
Replace
the
bezel
assembly.
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
180-xxx-002
Failed
diagnostics
LED
panel
test.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
180-xxx-003
Failed
system
board
LED
test.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
62
BladeCenter
HS21
Types
1885
and
8853:
Problem
Determination
and
Service
Guide
Содержание HS21 - BladeCenter - 8853
Страница 1: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 8: ...vi BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 16: ...xiv BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 126: ...110 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 138: ...122 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 139: ......
Страница 140: ...Part Number 24R9701 Printed in USA 1P P N 24R9701...