Error
code
Description
Action
1808
Invalid
header.
1.
Run
the
Configuration/Setup
Utility
program
and
make
sure
that
interrupt
resource
settings
are
correct.
2.
Remove
each
I/O-expansion
card
one
at
a
time,
restarting
the
blade
server
each
time,
until
the
problem
is
isolated.
3.
If
a
Memory
and
I/O
Expansion
Blade
is
installed,
reseat
it.
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
Failed
I/O-expansion
card
b.
Memory
and
I/O
Expansion
Blade
(if
one
is
installed)
c.
(Trained
service
technician
only)
System
board
assembly
1962
Boot
sector
error,
no
operating
system
installed.
1.
Make
sure
that
a
bootable
operating
system
is
installed.
2.
Run
the
SAS
Attached
Disk
diagnostic
test.
3.
Reseat
the
hard
disk
drive.
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
Hard
disk
drive
b.
(Trained
service
technician
only)
System
board
assembly
5962
CD
or
DVD
drive
configuration
error.
1.
Run
the
Configuration/Setup
Utility
program,
select
Load
Default
Settings
,
and
save
the
settings.
2.
Check
the
function
of
the
shared
BladeCenter
unit
resources
(see
3.
Reseat
the
battery.
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
Battery
b.
(Trained
service
technician
only)
System
board
assembly
Chapter
2.
Diagnostics
31
Содержание HS21 - BladeCenter - 8853
Страница 1: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 8: ...vi BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 16: ...xiv BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 126: ...110 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 138: ...122 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 139: ......
Страница 140: ...Part Number 24R9701 Printed in USA 1P P N 24R9701...