Error
code
Description
Action
089-xxx-00n
Failed
microprocessor
test.
1.
(Trained
service
technician
only)
Reseat
microprocessor
1
if
n
=
0
or
6.
2.
(Trained
service
technician
only)
Reseat
microprocessor
2
if
n
=
1
or
7.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
(Trained
service
technician
only)
Microprocessor
1
if
n
=
0
or
6
b.
(Trained
service
technician
only)
Microprocessor
2
if
n
=
1
or
7
c.
(Trained
service
technician
only)
System
board
assembly
166-403-001
System
Management:
Failed
(BMC
indicates
failure
in
I2C
bus
test)
Shutdown
and
remove
the
blade
server
from
the
BladeCenter
unit,
wait
30
seconds;
then,
reinstall
the
blade
server
in
the
BladeCenter
unit
and
restart
it.
If
problem
persists,
perform
the
following
tasks
in
the
order
shown,
restarting
the
blade
server
each
time:
1.
Remove
the
cKVM
feature
card
(if
installed).
2.
Update
the
BMC
firmware.
3.
Update
the
Ethernet
controller
firmware.
4.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
166-404-001
System
Management:
Failed
(BMC
indicates
failure
in
I2C
bus
test)
Shutdown
and
remove
the
blade
server
from
the
BladeCenter
unit,
wait
30
seconds;
then,
reinstall
the
blade
server
in
the
BladeCenter
unit
and
restart
it.
If
problem
persists,
perform
the
following
tasks
in
the
order
shown,
restarting
the
blade
server
each
time:
1.
Update
the
BMC
firmware.
2.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
166-405-001
System
Management:
Failed
(BMC
indicates
failure
in
I2C
bus
test)
Shutdown
and
remove
the
blade
server
from
the
BladeCenter
unit,
wait
30
seconds;
then,
reinstall
the
blade
server
in
the
BladeCenter
unit
and
restart
it.
If
problem
persists,
perform
the
following
tasks
in
the
order
shown,
restarting
the
blade
server
each
time:
1.
Remove
the
cKVM
feature
card
(if
present).
2.
Update
the
BMC
firmware.
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
Chapter
2.
Diagnostics
59
Содержание HS21 - BladeCenter - 8853
Страница 1: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 8: ...vi BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 16: ...xiv BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 126: ...110 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 138: ...122 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 139: ......
Страница 140: ...Part Number 24R9701 Printed in USA 1P P N 24R9701...