v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
CRUs
and
which
components
are
FRUs.
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
00150900
SERR/PERR
Detected
on
PCI
bus
(no
source
found)
1.
If
a
Memory
and
I/O
Expansion
Blade
is
installed,
reseat
it.
2.
Reseat
each
I/O-expansion
card,
restarting
the
blade
server
each
time.
3.
Replace
the
following
components,
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
I/O-expansion
card
in
slot
xx
.
b.
Memory
and
I/O
Expansion
Blade
(if
one
is
installed).
c.
(Trained
service
technician
only)
System
board
assembly.
00151000
SERR:
Signaled
Target
Abort
Slot=
xx
Vendor
ID=
xxxx
Device
ID=
xxxx
Status=
xxxx
1.
If
a
Memory
and
I/O
Expansion
Blade
is
installed,
reseat
it.
2.
Reseat
the
I/O-expansion
card
in
slot
xx
;
then,
restart
the
blade
server.
3.
Replace
the
following
components,
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
I/O-expansion
card
in
slot
xx
b.
Memory
and
I/O
Expansion
Blade
(if
one
is
installed)
c.
(Trained
service
technician
only)
System
board
assembly
00151100
MCA:
Recoverable
Error
Detected
Proc=
xx
1.
Reseat
microprocessor
xx
.
2.
Replace
the
following
components,
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
(Trained
service
technician
only)
Microprocessor
xx
b.
(Trained
service
technician
only)
System
board
assembly
00151200
MCA:
Unrecoverable
Error
Detected
Proc=
xx
1.
(Trained
service
technician
only)
Reseat
microprocessor
xx
.
2.
Replace
the
following
components,
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
(Trained
service
technician
only)
Microprocessor
xx
b.
(Trained
service
technician
only)
System
board
assembly
Chapter
2.
Diagnostics
35
Содержание HS21 - BladeCenter - 8853
Страница 1: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 8: ...vi BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 16: ...xiv BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 126: ...110 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 138: ...122 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 139: ......
Страница 140: ...Part Number 24R9701 Printed in USA 1P P N 24R9701...