Error
code
Description
Action
178
EEPROM
not
functional
(Trained
service
technician
only)
Replace
the
system
board
assembly.
184
Bad
power-on
password.
1.
Run
the
Configuration/Setup
Utility
program,
select
Load
Default
Settings
,
and
save
the
settings.
2.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
185
Corrupted
boot
sequence
1.
Run
the
Configuration/Setup
Utility
program,
select
Load
Default
Settings
,
and
save
the
settings.
2.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
186
Security
hardware
control
logic
error
(Trained
service
technician
only)
Replace
the
system
board
assembly.
187
VPD
Serial
Number
not
set
(Trained
service
technician
only)
Replace
the
system
board
assembly.
188
Bad
EEPROM
CRC
#2
(Trained
service
technician
only)
Replace
the
system
board
assembly.
189
Three
attempts
to
enter
the
incorrect
password.
Restart
the
blade
server,
run
the
Configuration/Setup
Utility
program,
and
change
the
power-on
password.
196
Microprocessor
cache
mismatch
detected.
Make
sure
that
all
of
the
installed
microprocessors
are
of
the
same
type
and
cache
size.
If
they
are
not,
replace
one
of
the
microprocessors
with
a
microprocessor
of
the
same
type
and
cache
size
as
the
remaining
installed
microprocessor.
198
Microprocessor
speed
mismatch
detected.
Make
sure
that
all
of
the
installed
microprocessors
are
of
the
same
type
and
speed.
If
they
are
not,
replace
one
of
the
microprocessors
with
a
microprocessor
of
the
same
type
and
speed
as
the
remaining
installed
microprocessor.
199
Microprocessor
technology
mismatch
detected.
Make
sure
that
all
of
the
installed
microprocessors
belong
to
the
same
family.
If
they
are
not,
replace
the
microprocessor
that
has
the
wrong
technology.
201
Base
memory
error
or
extended
memory
error.
1.
Update
the
blade
server
firmware
and
restart
the
blade
server.
2.
Reseat
the
DIMMs.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
DIMMs
b.
(Trained
service
technician
only)
System
board
assembly
24
BladeCenter
HS21
Types
1885
and
8853:
Problem
Determination
and
Service
Guide
Содержание HS21 - BladeCenter - 8853
Страница 1: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 8: ...vi BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 16: ...xiv BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 126: ...110 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 138: ...122 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 139: ......
Страница 140: ...Part Number 24R9701 Printed in USA 1P P N 24R9701...