Table
5-1 (Page 7 of 9). Service Request Numbers
SRN
FRU List
%
Problem
60000
SSA adapter card (See the
installation and service guide
for the using system.)
100
Description: The SSA adapter is missing
from the expected configuration.
Action: Verify that the SSA adapter card
is installed in the expected slot of the
using-system.
If it is in the expected slot, exchange
the FRU for a new FRU.
If it is not in the expected slot, enter
the diag -a command, and answer the
questions that are displayed.
7
xxxx
Disk drive module (See
“Hot-Swappable Disk Drives”
on page 7-13.)
Backplane assembly (See
“SCSI or SSA Backplane” on
page 7-65.)
80
20
Description: An SP module is missing
from the expected configuration of the
SSA loop.
Action: Replace the FRUs one at a time.
Go to "MAP 410: Repair Checkout" in
Diagnostic Information for Multiple Bus
Systems to verify each repair.
D0000
Disk drive module (See
“Hot-Swappable Disk Drives”
on page 7-13.)
100
Description: The using system cannot
configure the disk drive module. This is
probably a software problem.
Action:
1. Try again to configure the disk drive
module.
2. If the problem remains, go to “Soft-
ware and Microcode Errors” on
page 5-2 before exchanging the FRU.
D0100
Disk drive module (See
“Hot-Swappable Disk Drives”
on page 7-13.)
100
Description: Unable to clear a disk drive
module reservation.
Action: Exchange the FRU for a new
FRU.
D0101
Disk drive module (See
“Hot-Swappable Disk Drives”
on page 7-13.)
100
Description: The disk drive module has
been reserved since the diagnostics
started. The disk drive module is in use.
Action: Release the disk drive module,
and run the diagnostics again.
D0200
Disk drive module (See
“Hot-Swappable Disk Drives”
on page 7-13.)
100
Description: The disk drive module timed
out while the diagnostics were running.
Action: Rerun the diagnostics. If the
problem remains, exchange the FRU for a
new FRU.
D0300
Disk drive module (See
“Hot-Swappable Disk Drives”
on page 7-13.)
100
Description: The disk drive module failed
the diagnostic test.
Action: Exchange the FRU for a new
FRU.
Chapter 5. SSA Software and Microcode Errors
5-9
Содержание H SERIES RS/6000
Страница 1: ...RS 6000 Enterprise Server Model H Series IBM Installation and Service Guide SA38 0547 01...
Страница 14: ...xiv RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 34: ...1 18 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 106: ...2 72 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 177: ...AIX and Physical Location Code Reference Table Model H50 Chapter 3 Error Code to FRU Index 3 71...
Страница 178: ...3 72 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 262: ...7 14 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 279: ...Chapter 7 Removal and Replacement Procedures 7 31...
Страница 299: ...Replacement To replace do the removal steps in the reverse order Chapter 7 Removal and Replacement Procedures 7 51...
Страница 315: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Страница 316: ...3 2 1 4 5 12 6 7 13 8 9 10 11 8 2 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 320: ...42 41 36 33 34 35 37 38 39 40 8 6 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 328: ...8 14 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 340: ...A 12 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 401: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix E Modem Configurations E 21...
Страница 408: ...E 28 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 412: ...F 4 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 419: ...Index X 7...
Страница 420: ...X 8 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Страница 423: ......