3746-900 MAPs
014 (continued)
¹
Wait until 'alarm xxxx FRU unplugged', and 'alarm xxxx FRU plugged' are displayed on the service
processor screen, then continue.
¹
On the "Confirmation" window, click on "OK".
¹
Return to the "Maintenance Options" window.
¹
On the window displayed select the "Perform Diagnostics on the resource" option and click on "OK".
¹
The "Test and Running Option Selection" window is displayed.
¹
Select the "LIC11 MAT" and click on "OK".
¹
An "Information Required" window is displayed prompting you to install a wrap plug.
¹
Install the wrap plug PN 58G9425 at the rear of the LIC11.
¹
Check if the two LEDs are ON.
Are the both LEDs of wrap plug ON?
Yes No
015
Call your support for assistance.
016
¹
Enter "Yes" on the information Required" window and click on "OK".
¹
The "Diagnostic Active Status" window is displayed few seconds. Then the "Information Required"
window prompts you to remove the wrap plug.
¹
Unplug the wrap plug and click on "OK".
¹
The "Diagnostic Active Status" window is displayed. When the test is complete an "Information
Message" gives the test result. Click on "OK".
¹
A "Diagnostic Warning" window remind you to remove the wrap plug.
¹
Unplug the wrap plug if not already done and click on "OK".
¹
The "Diagnostic Active Status" window is displayed with the number of errors.
Is the diagnostic error-free ?
Yes No
017
Call your support for assistance.
018
Go to “MAP: 3746-900 Ending Procedure in Concurrent Mode” on page 1-139.
019
¹
Click on "Cancel".
¹
Replug the cable coming from the LCBB on the rear of the LIC11 and secure it.
¹
On the "Maintenance Options" window, select the "Perform Diagnostics on the resource" option and
click on "OK".
¹
The "Test and Running Option Selection" window is displayed.
¹
Select the "LIC11 MAT" and click on "OK".
¹
An "Information Required" window is displayed prompting you to install a wrap plug.
¹
Locate the LCBB connected to this LIC11.
¹
On the LCBB unfasten the screws which maintain the cable coming from LIC11and unplug it.
¹
On the end of the cable install the wrap plug PN 58G9425.
¹
Check if the two LEDs are ON.
Are the both LEDs of wrap plug ON?
Yes No
020
Go to Step 024 on page 2-118.
021
(Step 021 continues)
Chapter 2. MAPs for FRU Isolation
2-117
Содержание FlashSystem 900
Страница 1: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Страница 2: ......
Страница 3: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Страница 14: ...xii 3746 900 Service Guide...
Страница 16: ...xiv 3746 900 Service Guide...
Страница 22: ...xx 3746 900 Service Guide...
Страница 29: ...Safety Figure 0 3 Ground Wire Connection On Controller Expansion SAFETY xxvii...
Страница 30: ...Safety Figure 0 4 Ground Wire Connection Between Attached Controller Expansions xxviii 3746 900 Service Guide...
Страница 31: ...Safety Figure 0 5 Ground Wire Connection Between Controller Expansions at less than Six Meters SAFETY xxix...
Страница 60: ...Safety lviii 3746 900 Service Guide...
Страница 61: ...Safety SAFETY lix...
Страница 62: ...Safety lx 3746 900 Service Guide...
Страница 63: ...Safety SAFETY lxi...
Страница 64: ...Safety lxii 3746 900 Service Guide...
Страница 65: ...Safety SAFETY lxiii...
Страница 66: ...Safety lxiv 3746 900 Service Guide...
Страница 67: ...Safety...
Страница 68: ...Safety lxvi 3746 900 Service Guide...
Страница 69: ...Safety SAFETY lxvii...
Страница 70: ...Safety lxviii 3746 900 Service Guide...
Страница 71: ...Safety...
Страница 72: ...Safety lxx 3746 900 Service Guide...
Страница 73: ...Safety SAFETY lxxi...
Страница 74: ...Safety lxxii 3746 900 Service Guide...
Страница 75: ...Safety SAFETY lxxiii...
Страница 76: ...Safety lxxiv 3746 900 Service Guide...
Страница 77: ...Safety SAFETY lxxv...
Страница 78: ...Safety lxxvi 3746 900 Service Guide...
Страница 80: ...Safety G F F H E Figure 0 24 3745 Label and Power Rating Plate Locations Front lxxviii 3746 900 Service Guide...
Страница 92: ...Safety xc 3746 900 Service Guide...
Страница 94: ...Safety xcii 3746 900 Service Guide...
Страница 129: ...3746 900 FRU Exchange 010 continued Go to MAP Ready LED ON on page 1 52 Chapter 1 START 1 35...
Страница 246: ...3746 900 Procedures 10 Click on OK in the following window 11 Return where do you come from 1 152 3746 900 Service Guide...
Страница 274: ...3746 900 MAPs 3746 900 48v DC DISTRIBUTION Figure 2 5 48 Volts DC Distribution 2 16 3746 900 Service Guide...
Страница 276: ...3746 900 MAPs Figure 2 6 CP2 Circuit 2 18 3746 900 Service Guide...
Страница 325: ...3746 900 MAPs 026 continued Go to Step 014 on page 2 65 Chapter 2 MAPs for FRU Isolation 2 67...
Страница 340: ...3746 900 MAPs 113 continued Go to Step 001 on page 2 68 2 82 3746 900 Service Guide...
Страница 414: ...Service Processor MAPs 2 156 3746 900 Service Guide...
Страница 484: ...FRU Exchange Figure 4 16 3746 Model 9x0 CBSP Cassette 4 18 3746 900 Service Guide...
Страница 491: ...FRU Exchange R e a r S i d e Figure 4 21 3746 900 Connectivity Switch and DCDC Chapter 4 3746 900 FRU Exchange 4 25...
Страница 495: ...FRU Exchange Figure 4 23 3746 900 Rear of DC Power Box Chapter 4 3746 900 FRU Exchange 4 29...
Страница 510: ...FRU Exchange Figure 4 39 3746 900 LIC16 Coupler 4 44 3746 900 Service Guide...
Страница 520: ...FRU Exchange Figure 4 45 3746 900 Transformer Handling 4 54 3746 900 Service Guide...
Страница 522: ...FRU Exchange 4 56 3746 900 Service Guide...
Страница 542: ......
Страница 545: ......