Service Processor MAPs
MAP 6020: How to Run 3746-900 Specific Diagnostics
Ask the customer to stop all the traffic on the 3746-900. If APPN/IP is installed, deactivate the ports
concerned (refer to “Activate/Deactivate a Resource Via CCM” on page 1-150), then continue the proce-
dure from here. These diagnostics must be run in Offline Mode.
This MAP only allows you to run either the MAT diagnostic on a specific coupler (ESCC, TIC3) or
diagnostics on the service logic (SAS Bus).
For all other diagnostics, use the “MAP 6010: How to run 3746-900 Diagnostic in Offline Mode” on
page 3-43.
001
¹
You should be logged ON on the service processor console. If not, go to “Console Use for
maintenance” on page 1-1 for logging ON and return here.
¹
Set the 3746-900 in Offline mode (if it is not already) as follows:
– Double click on the 3746-900 icon.
– The "3746-9x0 Menu" is displayed.
– Click on the "Problem Management" option.
– Double click on the "Set 3746-9x0 Online/Offline Option".
– On the "Set 3746-9x0 Online/Offline" window, click on "YES" or "NO" according to the current
setting.
– On the next "Set 3746-9x0 Online/Offline" window, click on "OK".
¹
If you set the 3746-900 in Offline mode in the previous step perform a general IML. Otherwise go to
Step 003
– Return to the "3746-9x0 Menu" window.
– Click on the "Operation Management" option.
– Double click on the "Perform General IML" option.
– A "Perform General IML", click on "YES" to perform an IML without diagnostics.
– A normal 3746-900 IML is terminated when 00000000 is displayed on the control panel and the
ready LED is ON. In case of problem during IML, a code is displayed on the control panel. This
code can be flashing or steady (more than 60 seconds) while the ready LED is blinking.
Is the ready LED come ON?
Yes No
002
Record the code displayed on the control panel and go to “3746-900 Control Panel Codes” on
page 1-15.
003
¹
Return to the "3746-9x0 Menu.
¹
Click on the "Problem Management" option.
¹
Double click on the "Perform Specific Diagnostics" option.
¹
On the "Diagnostic Control Monitor" window, select the option that you want.
– If you select "Run diagnostics for a specific hardware resource", go to Step 004.
– If you select "Run diagnostics for the Service Bus", go to Step 007 on page 3-46.
004
¹
On the "Resource Selector" window, select the resource and click on "OK".
¹
On the next "Resource Selector" window, select the resource again.
¹
On the "Test and Running Option Selection" the selected resource is displayed with "MAT" (Manual
Assurance Test) preselected. Click on "OK".
¹
A "Diagnostic Active Status" window is temporary displayed.
¹
When the "Information Required" window is displayed:
– Remove the cable at the rear of the ESCC or TIC3.
– Install the wrap plug on the rear of the coupler (PN 6165899 for TIC3 and PN 5605670 for ESCC).
(Step 004 continues)
Chapter 3. How to Run Diagnostics
3-45
Содержание FlashSystem 900
Страница 1: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Страница 2: ......
Страница 3: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Страница 14: ...xii 3746 900 Service Guide...
Страница 16: ...xiv 3746 900 Service Guide...
Страница 22: ...xx 3746 900 Service Guide...
Страница 29: ...Safety Figure 0 3 Ground Wire Connection On Controller Expansion SAFETY xxvii...
Страница 30: ...Safety Figure 0 4 Ground Wire Connection Between Attached Controller Expansions xxviii 3746 900 Service Guide...
Страница 31: ...Safety Figure 0 5 Ground Wire Connection Between Controller Expansions at less than Six Meters SAFETY xxix...
Страница 60: ...Safety lviii 3746 900 Service Guide...
Страница 61: ...Safety SAFETY lix...
Страница 62: ...Safety lx 3746 900 Service Guide...
Страница 63: ...Safety SAFETY lxi...
Страница 64: ...Safety lxii 3746 900 Service Guide...
Страница 65: ...Safety SAFETY lxiii...
Страница 66: ...Safety lxiv 3746 900 Service Guide...
Страница 67: ...Safety...
Страница 68: ...Safety lxvi 3746 900 Service Guide...
Страница 69: ...Safety SAFETY lxvii...
Страница 70: ...Safety lxviii 3746 900 Service Guide...
Страница 71: ...Safety...
Страница 72: ...Safety lxx 3746 900 Service Guide...
Страница 73: ...Safety SAFETY lxxi...
Страница 74: ...Safety lxxii 3746 900 Service Guide...
Страница 75: ...Safety SAFETY lxxiii...
Страница 76: ...Safety lxxiv 3746 900 Service Guide...
Страница 77: ...Safety SAFETY lxxv...
Страница 78: ...Safety lxxvi 3746 900 Service Guide...
Страница 80: ...Safety G F F H E Figure 0 24 3745 Label and Power Rating Plate Locations Front lxxviii 3746 900 Service Guide...
Страница 92: ...Safety xc 3746 900 Service Guide...
Страница 94: ...Safety xcii 3746 900 Service Guide...
Страница 129: ...3746 900 FRU Exchange 010 continued Go to MAP Ready LED ON on page 1 52 Chapter 1 START 1 35...
Страница 246: ...3746 900 Procedures 10 Click on OK in the following window 11 Return where do you come from 1 152 3746 900 Service Guide...
Страница 274: ...3746 900 MAPs 3746 900 48v DC DISTRIBUTION Figure 2 5 48 Volts DC Distribution 2 16 3746 900 Service Guide...
Страница 276: ...3746 900 MAPs Figure 2 6 CP2 Circuit 2 18 3746 900 Service Guide...
Страница 325: ...3746 900 MAPs 026 continued Go to Step 014 on page 2 65 Chapter 2 MAPs for FRU Isolation 2 67...
Страница 340: ...3746 900 MAPs 113 continued Go to Step 001 on page 2 68 2 82 3746 900 Service Guide...
Страница 414: ...Service Processor MAPs 2 156 3746 900 Service Guide...
Страница 484: ...FRU Exchange Figure 4 16 3746 Model 9x0 CBSP Cassette 4 18 3746 900 Service Guide...
Страница 491: ...FRU Exchange R e a r S i d e Figure 4 21 3746 900 Connectivity Switch and DCDC Chapter 4 3746 900 FRU Exchange 4 25...
Страница 495: ...FRU Exchange Figure 4 23 3746 900 Rear of DC Power Box Chapter 4 3746 900 FRU Exchange 4 29...
Страница 510: ...FRU Exchange Figure 4 39 3746 900 LIC16 Coupler 4 44 3746 900 Service Guide...
Страница 520: ...FRU Exchange Figure 4 45 3746 900 Transformer Handling 4 54 3746 900 Service Guide...
Страница 522: ...FRU Exchange 4 56 3746 900 Service Guide...
Страница 542: ......
Страница 545: ......