3746-900 MAPs
020 (continued)
Is the 3746-900 powering ON now ?
Yes No
021
Is CB1 tripping again?
Yes No
022
Go to Step 005.
023
Check that the machine is correctly wired
for the customer's input voltage. Refer to
Figure 2-1 on page 2-4. Check the ac
main voltage on the TB1 of the transformer.
Between pin and pinif input is
1
2
200 v
1
3
220 v
1
4
240 v
If the voltage is correct exchange the ACPW
box, go to “3746-900 Maintenance Using a
FRU list” on page 1-28. Refer to YZ page
105 for an eventual transformer problem.
024
Go to “CE Leaving Procedure” on page 4-55 to
return the machine to the customer. If the
problem is still present, contact your support.
025
Is the STANDBY light permanently ON?
Yes No
026
Is the STANDBY light blinking?
Yes No
027
Go to Step 038.
028
Is the SERVICE PROCESSOR NOT
ACCESSIBLE digit ON?
Yes No
029
Is the CBSA CHECK light ON?
Yes No
030
Note the 3746-900 control
panel code. Go to “3746-900
Control Panel Codes” on
page 1-15 and perform the
action required.
031
Exchange the CBSP. Go to
“3746-900 Maintenance Using a FRU
list” on page 1-28.
032
Go to “MAP 2750: 3746-900 Permanent
Service Processor Link Problem” on
page 2-94.
033
– Look at the power control window on the
3746-900 control panel and check the mode
validity.
(1) for remote
(3) for Local.
Is the power mode in 'remote' ?
Yes No
034
Are you here because you have a
problem putting the 3746-900 power ON
in 'local' mode?
Yes No
035
Press the 'Power Control' key until 1
('remote' mode) is displayed in the
power control window. Then press
the 'Validate' key. Try to power ON
again.
036
Go to “MAP 5120: 3746-900 Power ON
Problem in Local Mode” on page 2-13.
037
Go to “MAP 5110: 3746-900 Power ON Problem
in Remote Mode” on page 2-8.
038
Is the READY indicator blinking ?
Yes No
039
The READY LED is ON, the 3746-900
power ON is completed.
040
The 3746-900 has received a power ON
command.
(Step 040 continues)
2-6
3746-900: Service Guide
Содержание FlashSystem 900
Страница 1: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Страница 2: ......
Страница 3: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Страница 14: ...xii 3746 900 Service Guide...
Страница 16: ...xiv 3746 900 Service Guide...
Страница 22: ...xx 3746 900 Service Guide...
Страница 29: ...Safety Figure 0 3 Ground Wire Connection On Controller Expansion SAFETY xxvii...
Страница 30: ...Safety Figure 0 4 Ground Wire Connection Between Attached Controller Expansions xxviii 3746 900 Service Guide...
Страница 31: ...Safety Figure 0 5 Ground Wire Connection Between Controller Expansions at less than Six Meters SAFETY xxix...
Страница 60: ...Safety lviii 3746 900 Service Guide...
Страница 61: ...Safety SAFETY lix...
Страница 62: ...Safety lx 3746 900 Service Guide...
Страница 63: ...Safety SAFETY lxi...
Страница 64: ...Safety lxii 3746 900 Service Guide...
Страница 65: ...Safety SAFETY lxiii...
Страница 66: ...Safety lxiv 3746 900 Service Guide...
Страница 67: ...Safety...
Страница 68: ...Safety lxvi 3746 900 Service Guide...
Страница 69: ...Safety SAFETY lxvii...
Страница 70: ...Safety lxviii 3746 900 Service Guide...
Страница 71: ...Safety...
Страница 72: ...Safety lxx 3746 900 Service Guide...
Страница 73: ...Safety SAFETY lxxi...
Страница 74: ...Safety lxxii 3746 900 Service Guide...
Страница 75: ...Safety SAFETY lxxiii...
Страница 76: ...Safety lxxiv 3746 900 Service Guide...
Страница 77: ...Safety SAFETY lxxv...
Страница 78: ...Safety lxxvi 3746 900 Service Guide...
Страница 80: ...Safety G F F H E Figure 0 24 3745 Label and Power Rating Plate Locations Front lxxviii 3746 900 Service Guide...
Страница 92: ...Safety xc 3746 900 Service Guide...
Страница 94: ...Safety xcii 3746 900 Service Guide...
Страница 129: ...3746 900 FRU Exchange 010 continued Go to MAP Ready LED ON on page 1 52 Chapter 1 START 1 35...
Страница 246: ...3746 900 Procedures 10 Click on OK in the following window 11 Return where do you come from 1 152 3746 900 Service Guide...
Страница 274: ...3746 900 MAPs 3746 900 48v DC DISTRIBUTION Figure 2 5 48 Volts DC Distribution 2 16 3746 900 Service Guide...
Страница 276: ...3746 900 MAPs Figure 2 6 CP2 Circuit 2 18 3746 900 Service Guide...
Страница 325: ...3746 900 MAPs 026 continued Go to Step 014 on page 2 65 Chapter 2 MAPs for FRU Isolation 2 67...
Страница 340: ...3746 900 MAPs 113 continued Go to Step 001 on page 2 68 2 82 3746 900 Service Guide...
Страница 414: ...Service Processor MAPs 2 156 3746 900 Service Guide...
Страница 484: ...FRU Exchange Figure 4 16 3746 Model 9x0 CBSP Cassette 4 18 3746 900 Service Guide...
Страница 491: ...FRU Exchange R e a r S i d e Figure 4 21 3746 900 Connectivity Switch and DCDC Chapter 4 3746 900 FRU Exchange 4 25...
Страница 495: ...FRU Exchange Figure 4 23 3746 900 Rear of DC Power Box Chapter 4 3746 900 FRU Exchange 4 29...
Страница 510: ...FRU Exchange Figure 4 39 3746 900 LIC16 Coupler 4 44 3746 900 Service Guide...
Страница 520: ...FRU Exchange Figure 4 45 3746 900 Transformer Handling 4 54 3746 900 Service Guide...
Страница 522: ...FRU Exchange 4 56 3746 900 Service Guide...
Страница 542: ......
Страница 545: ......