3746-900 FRU Exchange
007 (continued)
¹
Unfasten the screws which maintain the cable at the rear of LIC12 and unplug the cable from the
LIC12.
¹
At the rear of the LIC12 install the wrap plug according to the type of connection that you have.
– Wrap plug PN 58X9354 for X.21
– Wrap plug PN 58X9349 for V.35
(If you do not know which kind of connection you have, install either one of these wraps).
¹
Enter "Yes" on the "Information Required" window and click on "OK".
¹
The "Diagnostic Active Status" window is displayed. When the test is complete, an "Information
Message" gives the test result. Click on "OK".
¹
A "Diagnostic Warning" window asks you to remove the wrap plug.
¹
Unplug the wrap plug and click on "OK".
¹
The "Diagnostic Active Status" window is displayed with the number of errors.
Is the diagnostic error-free ?
Yes No
008
¹
Using the "Cancel" key, return to the "Maintenance Options" window and select the "Replace the
Resource" option.
¹
A "Confirmation" window is displayed.
¹
Go to Chapter 4, “3746-900 FRU Exchange” on page 4-1 for the FRU replacement. After the
FRU replacement, continue with Step 023 on page 1-105.
009
¹
If you have installed the wrap plug according to the type of connection continue with Step 011.
¹
Otherwise continue this procedure.
Did you run the LIC12 MAT diagnostic using the two wraps plugs?
Yes No
010
Go to Step 007 on page 1-103 to run the diagnostic again using the other wrap plug.
011
Do you have ONLY this FRU in your FRU list?
Yes No
012
Reconnect and secure the cable at the rear of LIC12.
Is there any other FRU in your FRU list to test?
Yes No
013
You have tested all the FRU of your FRU list and all are error free.
Go to “MAP: No Problem Found on All the FRUS with Diagnostics in Concurrent Mode” on
page 1-130
014
Is there any other processor or CS in your FRU list?
Yes No
015
Go to “3746-900 FRU list for exchange” on page 1-55 to select the next FRU.
016
Go to “MAP: 3746-900 in Offline Mode” on page 1-124
017
No error detected on the suspected FRU using the concurrent mode diagnostics. Change the FRU,
1-104
3746-900: Service Guide
Содержание FlashSystem 900
Страница 1: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Страница 2: ......
Страница 3: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Страница 14: ...xii 3746 900 Service Guide...
Страница 16: ...xiv 3746 900 Service Guide...
Страница 22: ...xx 3746 900 Service Guide...
Страница 29: ...Safety Figure 0 3 Ground Wire Connection On Controller Expansion SAFETY xxvii...
Страница 30: ...Safety Figure 0 4 Ground Wire Connection Between Attached Controller Expansions xxviii 3746 900 Service Guide...
Страница 31: ...Safety Figure 0 5 Ground Wire Connection Between Controller Expansions at less than Six Meters SAFETY xxix...
Страница 60: ...Safety lviii 3746 900 Service Guide...
Страница 61: ...Safety SAFETY lix...
Страница 62: ...Safety lx 3746 900 Service Guide...
Страница 63: ...Safety SAFETY lxi...
Страница 64: ...Safety lxii 3746 900 Service Guide...
Страница 65: ...Safety SAFETY lxiii...
Страница 66: ...Safety lxiv 3746 900 Service Guide...
Страница 67: ...Safety...
Страница 68: ...Safety lxvi 3746 900 Service Guide...
Страница 69: ...Safety SAFETY lxvii...
Страница 70: ...Safety lxviii 3746 900 Service Guide...
Страница 71: ...Safety...
Страница 72: ...Safety lxx 3746 900 Service Guide...
Страница 73: ...Safety SAFETY lxxi...
Страница 74: ...Safety lxxii 3746 900 Service Guide...
Страница 75: ...Safety SAFETY lxxiii...
Страница 76: ...Safety lxxiv 3746 900 Service Guide...
Страница 77: ...Safety SAFETY lxxv...
Страница 78: ...Safety lxxvi 3746 900 Service Guide...
Страница 80: ...Safety G F F H E Figure 0 24 3745 Label and Power Rating Plate Locations Front lxxviii 3746 900 Service Guide...
Страница 92: ...Safety xc 3746 900 Service Guide...
Страница 94: ...Safety xcii 3746 900 Service Guide...
Страница 129: ...3746 900 FRU Exchange 010 continued Go to MAP Ready LED ON on page 1 52 Chapter 1 START 1 35...
Страница 246: ...3746 900 Procedures 10 Click on OK in the following window 11 Return where do you come from 1 152 3746 900 Service Guide...
Страница 274: ...3746 900 MAPs 3746 900 48v DC DISTRIBUTION Figure 2 5 48 Volts DC Distribution 2 16 3746 900 Service Guide...
Страница 276: ...3746 900 MAPs Figure 2 6 CP2 Circuit 2 18 3746 900 Service Guide...
Страница 325: ...3746 900 MAPs 026 continued Go to Step 014 on page 2 65 Chapter 2 MAPs for FRU Isolation 2 67...
Страница 340: ...3746 900 MAPs 113 continued Go to Step 001 on page 2 68 2 82 3746 900 Service Guide...
Страница 414: ...Service Processor MAPs 2 156 3746 900 Service Guide...
Страница 484: ...FRU Exchange Figure 4 16 3746 Model 9x0 CBSP Cassette 4 18 3746 900 Service Guide...
Страница 491: ...FRU Exchange R e a r S i d e Figure 4 21 3746 900 Connectivity Switch and DCDC Chapter 4 3746 900 FRU Exchange 4 25...
Страница 495: ...FRU Exchange Figure 4 23 3746 900 Rear of DC Power Box Chapter 4 3746 900 FRU Exchange 4 29...
Страница 510: ...FRU Exchange Figure 4 39 3746 900 LIC16 Coupler 4 44 3746 900 Service Guide...
Страница 520: ...FRU Exchange Figure 4 45 3746 900 Transformer Handling 4 54 3746 900 Service Guide...
Страница 522: ...FRU Exchange 4 56 3746 900 Service Guide...
Страница 542: ......
Страница 545: ......