FRU Exchange
Exchange a DCPW
Important
Check that the 'Power Control' display is
set to local (3) on the control panel.
If not, do the following:
¹
Press the 'Power Control' key until (3) is
displayed in the power control window.
¹
Press the 'Validate' key.
If the state of the machine does not allow you
to display or to change the 'Power control'
mode, continue with the following procedure.
1. If the machine has its
¹
Ready LED ON, go to step 2.
¹
Otherwise, go to step 3.
2. Activate the maintenance switch.
a. Open the front cover and locate the lever
of the maintenance switch on the
DCDP.
.1/
b. Pull the lever outwards.
This will prevent the main -48v from drop-
ping and will stop the power monitoring.
3. Locate the DCPW that you have to exchange
using Figure 4-9 on page 4-8.
4. Switch the main circuit breaker CB1 OFF at
the DCPW.
.2/
5. Switch the -48 Volts DC source circuit breaker
OFF or ask the customer to do so..
6. Attach a warning label directly to the circuit
breaker indicating that "power must not be
applied".
7. Disconnect the power supply cable from the
customer junction box.
8. At the rear of the machine, loosen the four
screws which secure the cover plate.
9. Remove the cover plate.
10. Check that on the rear TB of the DCPW there
is no voltage
.3/
between the black and red
wire.
11. Disconnect the black and the red wire from
the DCPW.
.3/
12. Unplug connectors J9 and J10 from the rear
of the DCDP.
13. Remove the screw holding the DCPW.
.4/
14. At the front of the machine, unplug the J1
connector and remove the two screws holding
the power box. Slide the DCPW out.
To install the new DCPW, perform this procedure
in the reverse order.
¹
Return to the step in the MAP you were per-
forming.
4-28
3746-900: Service Guide
Содержание FlashSystem 900
Страница 1: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Страница 2: ......
Страница 3: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Страница 14: ...xii 3746 900 Service Guide...
Страница 16: ...xiv 3746 900 Service Guide...
Страница 22: ...xx 3746 900 Service Guide...
Страница 29: ...Safety Figure 0 3 Ground Wire Connection On Controller Expansion SAFETY xxvii...
Страница 30: ...Safety Figure 0 4 Ground Wire Connection Between Attached Controller Expansions xxviii 3746 900 Service Guide...
Страница 31: ...Safety Figure 0 5 Ground Wire Connection Between Controller Expansions at less than Six Meters SAFETY xxix...
Страница 60: ...Safety lviii 3746 900 Service Guide...
Страница 61: ...Safety SAFETY lix...
Страница 62: ...Safety lx 3746 900 Service Guide...
Страница 63: ...Safety SAFETY lxi...
Страница 64: ...Safety lxii 3746 900 Service Guide...
Страница 65: ...Safety SAFETY lxiii...
Страница 66: ...Safety lxiv 3746 900 Service Guide...
Страница 67: ...Safety...
Страница 68: ...Safety lxvi 3746 900 Service Guide...
Страница 69: ...Safety SAFETY lxvii...
Страница 70: ...Safety lxviii 3746 900 Service Guide...
Страница 71: ...Safety...
Страница 72: ...Safety lxx 3746 900 Service Guide...
Страница 73: ...Safety SAFETY lxxi...
Страница 74: ...Safety lxxii 3746 900 Service Guide...
Страница 75: ...Safety SAFETY lxxiii...
Страница 76: ...Safety lxxiv 3746 900 Service Guide...
Страница 77: ...Safety SAFETY lxxv...
Страница 78: ...Safety lxxvi 3746 900 Service Guide...
Страница 80: ...Safety G F F H E Figure 0 24 3745 Label and Power Rating Plate Locations Front lxxviii 3746 900 Service Guide...
Страница 92: ...Safety xc 3746 900 Service Guide...
Страница 94: ...Safety xcii 3746 900 Service Guide...
Страница 129: ...3746 900 FRU Exchange 010 continued Go to MAP Ready LED ON on page 1 52 Chapter 1 START 1 35...
Страница 246: ...3746 900 Procedures 10 Click on OK in the following window 11 Return where do you come from 1 152 3746 900 Service Guide...
Страница 274: ...3746 900 MAPs 3746 900 48v DC DISTRIBUTION Figure 2 5 48 Volts DC Distribution 2 16 3746 900 Service Guide...
Страница 276: ...3746 900 MAPs Figure 2 6 CP2 Circuit 2 18 3746 900 Service Guide...
Страница 325: ...3746 900 MAPs 026 continued Go to Step 014 on page 2 65 Chapter 2 MAPs for FRU Isolation 2 67...
Страница 340: ...3746 900 MAPs 113 continued Go to Step 001 on page 2 68 2 82 3746 900 Service Guide...
Страница 414: ...Service Processor MAPs 2 156 3746 900 Service Guide...
Страница 484: ...FRU Exchange Figure 4 16 3746 Model 9x0 CBSP Cassette 4 18 3746 900 Service Guide...
Страница 491: ...FRU Exchange R e a r S i d e Figure 4 21 3746 900 Connectivity Switch and DCDC Chapter 4 3746 900 FRU Exchange 4 25...
Страница 495: ...FRU Exchange Figure 4 23 3746 900 Rear of DC Power Box Chapter 4 3746 900 FRU Exchange 4 29...
Страница 510: ...FRU Exchange Figure 4 39 3746 900 LIC16 Coupler 4 44 3746 900 Service Guide...
Страница 520: ...FRU Exchange Figure 4 45 3746 900 Transformer Handling 4 54 3746 900 Service Guide...
Страница 522: ...FRU Exchange 4 56 3746 900 Service Guide...
Страница 542: ......
Страница 545: ......