3746-900 FRU Exchange
043
¹
Press the 'Start' key on the 3746-900 control panel. An IML is started. A normal IML is terminated
when 00000000 is displayed on the control panel and the ready LED comes ON after about 3 minutes.
In case of a problem during IML, a code is displayed on the control panel. This code can be flashing
or steady (more than 60 seconds) while the ready LED is blinking.
Does the ready LED come ON?
Yes No
044
Check that you followed the FRU exchange procedure. If you do not identify the problem. Suspect
a FRU that you have installed and call your support.
045
¹
Run all the diagnostics on the 3746-900.
– Return to the "3746-9x0 Menu" window.
– Click on the "Problem Management" option.
– Double click on the "Perform Offline Diagnostics" option.
– The "Diagnostics" window is displayed. Select the "Whole 3746-900" and the "no wrap" options.
Then click on "Start".
– The "Diagnostics" window is displayed again and the "Elapsed time" is incremented during test
duration (see “Note:” on page 1-129).
– At the end of the test, the number of errors is indicated by an arrow.
Is the diagnostic error-free?
Yes No
046
¹
Suspect an FRU that you changed.
¹
Display the list of suspected FRUs. (See “Display the FRU List After a Diagnostic Failure” on
page 1-154 for procedure).
¹
Select the FRU with the highest fault probability.
¹
Restart the procedure, refer to “MAP: 3746-900 in Offline Mode” on page 1-124.
047
Problem solved. Go to “MAP: 3746-900 Ending Procedure In Offline Mode” on page 1-137.
048
¹
Run all the diagnostics on the 3746-900.
– Return to the "3746-9x0 Menu" window.
– Click on the "Problem Management" option.
– Double click on the "Perform Offline Diagnostics" option.
– The "Diagnostics" window is displayed. Select the "Whole 3746-900" and the "no wrap" options.
Then click on "Start".
– The "Diagnostics" window is displayed again and the "Elapsed time" is incremented during test
duration (see “Note:” on page 1-129).
– At the end of the test, the number of errors is indicated by an arrow.
Is the diagnostic error-free?
Yes No
049
Is there another FRU to test in your FRU list?
Yes No
050
Call for assistance.
051
(Step 051 continues)
1-128
3746-900: Service Guide
Содержание FlashSystem 900
Страница 1: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Страница 2: ......
Страница 3: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Страница 14: ...xii 3746 900 Service Guide...
Страница 16: ...xiv 3746 900 Service Guide...
Страница 22: ...xx 3746 900 Service Guide...
Страница 29: ...Safety Figure 0 3 Ground Wire Connection On Controller Expansion SAFETY xxvii...
Страница 30: ...Safety Figure 0 4 Ground Wire Connection Between Attached Controller Expansions xxviii 3746 900 Service Guide...
Страница 31: ...Safety Figure 0 5 Ground Wire Connection Between Controller Expansions at less than Six Meters SAFETY xxix...
Страница 60: ...Safety lviii 3746 900 Service Guide...
Страница 61: ...Safety SAFETY lix...
Страница 62: ...Safety lx 3746 900 Service Guide...
Страница 63: ...Safety SAFETY lxi...
Страница 64: ...Safety lxii 3746 900 Service Guide...
Страница 65: ...Safety SAFETY lxiii...
Страница 66: ...Safety lxiv 3746 900 Service Guide...
Страница 67: ...Safety...
Страница 68: ...Safety lxvi 3746 900 Service Guide...
Страница 69: ...Safety SAFETY lxvii...
Страница 70: ...Safety lxviii 3746 900 Service Guide...
Страница 71: ...Safety...
Страница 72: ...Safety lxx 3746 900 Service Guide...
Страница 73: ...Safety SAFETY lxxi...
Страница 74: ...Safety lxxii 3746 900 Service Guide...
Страница 75: ...Safety SAFETY lxxiii...
Страница 76: ...Safety lxxiv 3746 900 Service Guide...
Страница 77: ...Safety SAFETY lxxv...
Страница 78: ...Safety lxxvi 3746 900 Service Guide...
Страница 80: ...Safety G F F H E Figure 0 24 3745 Label and Power Rating Plate Locations Front lxxviii 3746 900 Service Guide...
Страница 92: ...Safety xc 3746 900 Service Guide...
Страница 94: ...Safety xcii 3746 900 Service Guide...
Страница 129: ...3746 900 FRU Exchange 010 continued Go to MAP Ready LED ON on page 1 52 Chapter 1 START 1 35...
Страница 246: ...3746 900 Procedures 10 Click on OK in the following window 11 Return where do you come from 1 152 3746 900 Service Guide...
Страница 274: ...3746 900 MAPs 3746 900 48v DC DISTRIBUTION Figure 2 5 48 Volts DC Distribution 2 16 3746 900 Service Guide...
Страница 276: ...3746 900 MAPs Figure 2 6 CP2 Circuit 2 18 3746 900 Service Guide...
Страница 325: ...3746 900 MAPs 026 continued Go to Step 014 on page 2 65 Chapter 2 MAPs for FRU Isolation 2 67...
Страница 340: ...3746 900 MAPs 113 continued Go to Step 001 on page 2 68 2 82 3746 900 Service Guide...
Страница 414: ...Service Processor MAPs 2 156 3746 900 Service Guide...
Страница 484: ...FRU Exchange Figure 4 16 3746 Model 9x0 CBSP Cassette 4 18 3746 900 Service Guide...
Страница 491: ...FRU Exchange R e a r S i d e Figure 4 21 3746 900 Connectivity Switch and DCDC Chapter 4 3746 900 FRU Exchange 4 25...
Страница 495: ...FRU Exchange Figure 4 23 3746 900 Rear of DC Power Box Chapter 4 3746 900 FRU Exchange 4 29...
Страница 510: ...FRU Exchange Figure 4 39 3746 900 LIC16 Coupler 4 44 3746 900 Service Guide...
Страница 520: ...FRU Exchange Figure 4 45 3746 900 Transformer Handling 4 54 3746 900 Service Guide...
Страница 522: ...FRU Exchange 4 56 3746 900 Service Guide...
Страница 542: ......
Страница 545: ......