Chapter 6. Solving problems
111
On
CPU
One of the microprocessors has failed,
or a microprocessor is installed in the
wrong connector.
1.
Check the microprocessor error
LEDs on the memory board. If a
microprocessor error LED is on
for a microprocessor connector
that has a terminator card
installed instead of a
microprocessor, the
microprocessors are not installed
in the correct order. See
“Installing a microprocessor” on
page 55 for information about the
correct order for installing
microprocessors. Otherwise,
continue with the next step.
2.
Turn off the server, reseat the
microprocessor indicated by the
lit microprocessor error LED, and
restart the server.
3.
If the problem persists, replace
the microprocessor.
If the problem persists, have the
system serviced.
On
FAN
One of the fans has failed or is
operating too slowly.
Note:
A failing fan can also cause
the TEMP and DASD LEDs to
be on.
The LED on the failing fan will be lit.
Replace the fan.
On
TEMP
The system temperature has exceeded
the maximum rating.
1.
Check to see if a fan has failed. If
it has, replace the fan.
2.
Make sure the room temperature
is not too high. (See “Chapter 1.
Introducing the xSeries 350
server,” on page 1.)
If the problem persists, have the
system serviced.
On
NON RED
The server is operating in a
nonredundant power mode. Two or
more power supplies are installed in
the server, and either one power
supply has failed or the server has
reached a condition in which it is no
longer operating in redundant mode.
If a power supply has failed, replace
the failing power supply. If not, add a
power supply to ensure redundancy.
On
OVER SPEC
The server is drawing more power
than the power supplies are rated for.
Either add a power supply or remove
a device from the server.
On
PS1
The first power supply has failed.
Replace the first power supply.
On
PS2
The second power supply has failed.
Replace the second power supply.
On
PS3
The third power supply has failed.
Replace the third power supply.
Table 17. Light Path Diagnostics.
System error
LED (on the
information LED
panel)
Diagnostics
panel LED on
Cause
Action
Содержание eserver xSeries 350
Страница 1: ...User s Reference xSeries 350 ...
Страница 2: ......
Страница 3: ...IBM IBM xSeries 350 User s Reference SC21 P902 60 ...
Страница 12: ...x IBM xSeries 350 User s Reference ...
Страница 22: ...10 IBM xSeries 350 User s Reference ...
Страница 34: ...22 IBM xSeries 350 User s Reference ...
Страница 40: ...28 IBM xSeries 350 User s Reference ...
Страница 90: ...78 IBM xSeries 350 User s Reference ...
Страница 148: ...136 IBM xSeries 350 User s Reference ...
Страница 154: ...142 IBM xSeries 350 User s Reference ...
Страница 170: ...158 IBM xSeries 350 User s Reference ...
Страница 173: ......
Страница 174: ...IBM Part Number 21P9026 21P9 26 ...