An error occurred during POST memory tests and a failing DIMM was disabled.
Note:
You can use the server with decreased memory.
Action:
1.
If you just installed memory, verify that the new memory is correct for your server.
Also verify that the memory is installed and seated correctly. Start the
Configuration/Setup Utility program and select Memory Settings from the
Advanced Setup
menu to enable the DIMM.
2.
If the problem remains, replace the failing DIMM.
If the problem persists, call for service.
301
303
An error occurred during the keyboard and keyboard controller test. These error messages also
might be accompanied by continuous beeping.
Action:
Ensure that:
•
Nothing is resting on the keyboard and pressing a key.
•
No key is stuck.
•
The keyboard cable is connected correctly to the keyboard and to the correct
connector on the server.
Running the diagnostic tests can isolate the server component that failed, but you must have
your system serviced. If the error message remains, call for service.
Note:
If you just connected a new mouse or other pointing device, turn off the server and
disconnect that device. Wait at least 5 seconds; then, turn on the server. If the error
message goes away, replace the device.
602
Invalid diskette boot record
Action:
1.
Replace the diskette.
2.
If the problem persists, make sure that the diskette drive cables are correctly and
securely connected.
3.
If the problem remains, replace the diskette drive.
If the problem persists, call for service.
604
An error occurred during a diskette drive test.
Action:
1.
Verify that the Configuration/Setup Utility program correctly reflects the type of
diskette drive that you have installed.
2.
Run the diagnostic tests. If the diagnostic tests fail, call for service.
662
A diskette drive configuration error occurred.
Action:
If you removed a diskette drive, make sure that the diskette drive setting is correct in the
Configuration/Setup Utility program. If the setting is not correct, change it.
If the problem persists, call for service.
962
A parallel port configuration error occurred.
Action:
If you changed a hardware option, make sure that the parallel port setting is correct in
the Configuration/Setup Utility program. If the setting is not correct, change it.
If the problem persists, call for service.
Table 16. POST error messages.
POST message
Description
Содержание eserver xSeries 350
Страница 1: ...User s Reference xSeries 350 ...
Страница 2: ......
Страница 3: ...IBM IBM xSeries 350 User s Reference SC21 P902 60 ...
Страница 12: ...x IBM xSeries 350 User s Reference ...
Страница 22: ...10 IBM xSeries 350 User s Reference ...
Страница 34: ...22 IBM xSeries 350 User s Reference ...
Страница 40: ...28 IBM xSeries 350 User s Reference ...
Страница 90: ...78 IBM xSeries 350 User s Reference ...
Страница 148: ...136 IBM xSeries 350 User s Reference ...
Страница 154: ...142 IBM xSeries 350 User s Reference ...
Страница 170: ...158 IBM xSeries 350 User s Reference ...
Страница 173: ......
Страница 174: ...IBM Part Number 21P9026 21P9 26 ...