Chapter 6. Solving problems
107
The following table describes the ac and dc power LEDs.
AC power LED
DC power LED
Description and action
On
On
The power supply is on and operating correctly.
On
Off
There is a dc power problem.
Possible causes:
1.
The server is not turned on (the power LED is blinking on the front
of the server).
Action:
Press the power-control button to start the server.
2.
The power supply has failed.
Action:
Replace the power supply.
If the problem persists, have the system serviced.
Off
Off
There is an ac power problem.
Possible causes:
1.
There is no ac power to the power supply.
Actions:
Verify that:
•
The electrical cord is properly connected to the
server.
•
The electrical outlet functions properly.
2.
The power supply has failed.
Action:
Replace the power supply.
If the problem persists, have the system serviced.