Error
Code
Description
Action/
Possible
Failing
FRU
B1xx
4633
System
power
control
network
(SPCN)
failure
Action:
This
error
code
may
be
informational,
or
it
may
indicate
a
failure
in
the
SPCN
firmware
update.
Before
changing
any
parts,
examine
word
13
in
the
service
processor
error
log
entry,
or
bytes
68
and
69
in
the
AIX
error
log
entry.
For
detailed
instructions
on
finding
word
13
in
the
service
processor
error
log
entry,
or
bytes
68
and
69
in
the
AIX
error
log
entry,
see
error
code
If
the
error
code
(word
11
value)
is
B1394633,
and
the
word
13
value
is
2309xxxx,
this
is
an
informational
message.
No
action
is
required
by
the
customer
or
service
representative.
All
of
the
following
values
of
word
13
(or
bytes
68
and
69)
indicate
a
failure
of
an
SPCN
firmware
update:
A704:
The
SPCN
code
update
has
been
interrupted;
the
SPCN
firmware
update
terminates.
This
is
logged
in
the
AIX
error
log
as
a
firmware
event.
Action:
Stop
all
partitions.
Use
the
HMC
to
power
down
the
system.
Power
on
the
system
and
restart
all
partitions;
the
SPCN
code
update
will
restart
and
run
in
the
background.
A70E:
SPCN
(system
power
control
network)
flash
update
was
successful.
Actions:
This
is
an
informational
message;
no
action
is
required
by
the
customer
or
service
representative.
It
indicates
that
the
SPCN
code
flash
update
was
successful.
A710:
SPCN
command
″
RLI
″
failed;
this
indicates
a
loss
of
communication
with
the
SPCN
controller.
This
is
logged
in
the
AIX
error
log
as
a
firmware
event.
Action:
Stop
all
partitions.
Use
the
HMC
to
power
down
the
system.
Remove
the
350V
of
power
from
the
system
by
putting
the
UEPO
switch
into
the
OFF
position.
Place
the
UEPO
switch
into
the
ON
position.
Wait
five
minutes.
Use
the
HMC
to
power
on
the
system
.
Restart
at
least
one
partition.
The
SPCN
code
update
will
run
in
the
background.
If
this
error
code
(word
13
value)
reoccurs,
contact
service
support.
A711:
SPCN
command
″
DDB
″
failed;
this
indicates
a
loss
of
communication
with
the
SPCN
controller.
This
is
logged
in
the
AIX
error
log
as
a
firmware
event.
Actions:
Stop
all
partitions.
Use
the
HMC
to
power
down
the
system.
Remove
the
350V
of
power
from
the
system
by
placing
the
UEPO
switch
into
the
OFF
position.
Place
the
UEPO
switch
into
the
ON
position.
Wait
five
minutes.
Use
the
HMC
to
power
on
the
system.
Restart
at
least
one
partition.
The
SPCN
code
update
will
run
in
the
background.
If
this
error
code
(word
13
value)
reoccurs,
contact
service
support.
A712:
SPCN
command
″
QFS
″
failed.
This
is
logged
in
the
AIX
error
log
as
a
firmware
event.
Actions:
Stop
all
partitions.
Use
the
HMC
to
power
down
the
system.
Remove
the
350V
of
power
from
the
system
by
placing
the
UEPO
switch
into
the
OFF
position.
Place
the
UEPO
switch
into
the
ON
position.
Wait
five
minutes.
Use
the
HMC
to
power
on
the
system.
Restart
at
least
one
partition.
The
SPCN
code
update
will
run
in
the
background.
If
this
error
code
(word
13
value)
reoccurs,
contact
service
support.
A713:
No
power
subsystem
code
LID
was
found
in
the
firmware
image;
the
FRU
firmware
update
terminates.
This
is
logged
in
the
AIX
error
log
as
a
sysplanar0
error.
Actions:
Contact
service
support.
A715:
A
bad
power
subsystem
code
LID
was
found
in
the
firmware
image;
the
FRU
firmware
update
terminates.
This
is
logged
in
the
AIX
error
log
as
a
sysplanar0
error.
Actions:
Contact
service
support.
Error
code
B1xx
4633
continues
on
to
the
next
row.
754
Eserver
pSeries
690
Service
Guide
Содержание eserver pSeries 690
Страница 1: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Страница 2: ......
Страница 3: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Страница 12: ...x Eserver pSeries 690 Service Guide...
Страница 14: ...xii Eserver pSeries 690 Service Guide...
Страница 228: ...Step 1527 5 Call your next level of support 212 Eserver pSeries 690 Service Guide...
Страница 357: ...Step 1543 15 Call for support This ends the procedure Chapter 3 Maintenance Analysis Procedures 341...
Страница 362: ...Step 1545 15 Call for support This ends the procedure 346 Eserver pSeries 690 Service Guide...
Страница 365: ...Step 1546 15 Call for support This ends the procedure Chapter 3 Maintenance Analysis Procedures 349...
Страница 381: ...Step 154A 14 Turn off the power Chapter 3 Maintenance Analysis Procedures 365...
Страница 430: ...414 Eserver pSeries 690 Service Guide...
Страница 798: ...782 Eserver pSeries 690 Service Guide...
Страница 868: ...Media Subsystem Internal Cables 1021 p690 Cable Installation and Management 1022 852 Eserver pSeries 690 Service Guide...
Страница 910: ...MCM Installation Shorts Test Step 3 See L3 Cache Modules on page 898 894 Eserver pSeries 690 Service Guide...
Страница 923: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 907...
Страница 924: ...L3 Cache Shorts Test Step 5 908 Eserver pSeries 690 Service Guide...
Страница 926: ...L3 Cache Shorts Test Step 2 910 Eserver pSeries 690 Service Guide...
Страница 928: ...L3 Cache Shorts Test Step 4 912 Eserver pSeries 690 Service Guide...
Страница 929: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 913...
Страница 1055: ...7040 Model 681 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 1039...
Страница 1057: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 1041...
Страница 1061: ...Power Cabling Chapter 10 Parts Information 1045...
Страница 1090: ...1074 Eserver pSeries 690 Service Guide...
Страница 1094: ...1078 Eserver pSeries 690 Service Guide...
Страница 1109: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations 1093...
Страница 1122: ...1106 Eserver pSeries 690 Service Guide...
Страница 1123: ...Appendix E Ground Path The ground path for the pSeries 690 is shown in the following figure 1107...
Страница 1124: ...1108 Eserver pSeries 690 Service Guide...
Страница 1132: ...1116 Eserver pSeries 690 Service Guide...
Страница 1133: ......
Страница 1134: ...Printed in U S A February 2004 SA38 0589 05...