Error
Code
Description
Action/
Possible
Failing
FRU
20D1
000D
Hypervisor
function
to
get
time-of-day
failed
1.
Check
for
system
firmware
updates.
Apply
update
if
available.
2.
Contact
your
next
level
of
support
for
assistance.
20D1
000F
Hypervisor
call
to
reset
PHB
or
to
check
for
drawer
existence
failed
1.
Check
for
system
firmware
updates.
Apply
update
if
available.
2.
Contact
your
next
level
of
support
for
assistance.
20D1
0010
Stack
underflow
from
fiber
channel
adapter
1.
Check
for
microcode
updates
for
the
fiber
channel
adapter.
Apply
update
if
available.
2.
Check
for
system
firmware
updates.
Apply
update
if
available.
3.
Contact
your
next
level
of
support
for
assistance.
20D1
0011
A
recovery
operation
on
an
internal
I/O
control
chip
failed
1.
If
the
system
is
partitioned,
perform
a
hard
reset
on
the
partition
that
owns
the
drawer
specified
by
the
location
code
reported
with
the
error.
Reboot
the
partition.
If
the
error
reoccurs,
replace
the
I/O
planar
specified
by
the
location
code.
If
the
system
is
running
in
full
system
partition
mode,
or
an
HMC
is
not
attached
to
the
system,
reboot
the
system.
If
the
error
reoccurs,
replace
the
I/O
planar
specified
by
the
location
code.
2.
Call
service
support.
20D1
0012
Attention:
One
of
the
I/O
subsystems
has
been
disconnected
from
the
system
This
indicates
that
an
I/O
subsystem
that
was
previously
in
the
configuration
was
not
found
during
the
current
boot.
If
an
I/O
subsystem
has
been
removed,
this
code
is
an
informational
message.
If
this
message
occurs
during
a
system
boot
when
the
system’s
drawer
configuration
has
not
changed,
complete
the
following
steps:
1.
If
not
already
booted,
boot
the
system
and
match
the
I/O
subsystem
location
codes
reported
by
the
operating
system
to
the
subsystems
attached
to
the
CEC.
Check
the
SPCN
and
RIO
cabling
to
the
I/O
subsystems.
If
a
cabling
problem
is
found,
correct
it.
2.
Check
for
system
firmware
updates.
Apply
update
if
available.
3.
Contact
your
next
level
of
support
for
assistance.
20E0
0001
Privileged-access
password
entry
error.
The
password
has
been
entered
incorrectly.
Try
installing
the
password
again.
498
Eserver
pSeries
690
Service
Guide
Содержание eserver pSeries 690
Страница 1: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Страница 2: ......
Страница 3: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Страница 12: ...x Eserver pSeries 690 Service Guide...
Страница 14: ...xii Eserver pSeries 690 Service Guide...
Страница 228: ...Step 1527 5 Call your next level of support 212 Eserver pSeries 690 Service Guide...
Страница 357: ...Step 1543 15 Call for support This ends the procedure Chapter 3 Maintenance Analysis Procedures 341...
Страница 362: ...Step 1545 15 Call for support This ends the procedure 346 Eserver pSeries 690 Service Guide...
Страница 365: ...Step 1546 15 Call for support This ends the procedure Chapter 3 Maintenance Analysis Procedures 349...
Страница 381: ...Step 154A 14 Turn off the power Chapter 3 Maintenance Analysis Procedures 365...
Страница 430: ...414 Eserver pSeries 690 Service Guide...
Страница 798: ...782 Eserver pSeries 690 Service Guide...
Страница 868: ...Media Subsystem Internal Cables 1021 p690 Cable Installation and Management 1022 852 Eserver pSeries 690 Service Guide...
Страница 910: ...MCM Installation Shorts Test Step 3 See L3 Cache Modules on page 898 894 Eserver pSeries 690 Service Guide...
Страница 923: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 907...
Страница 924: ...L3 Cache Shorts Test Step 5 908 Eserver pSeries 690 Service Guide...
Страница 926: ...L3 Cache Shorts Test Step 2 910 Eserver pSeries 690 Service Guide...
Страница 928: ...L3 Cache Shorts Test Step 4 912 Eserver pSeries 690 Service Guide...
Страница 929: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 913...
Страница 1055: ...7040 Model 681 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 1039...
Страница 1057: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 1041...
Страница 1061: ...Power Cabling Chapter 10 Parts Information 1045...
Страница 1090: ...1074 Eserver pSeries 690 Service Guide...
Страница 1094: ...1078 Eserver pSeries 690 Service Guide...
Страница 1109: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations 1093...
Страница 1122: ...1106 Eserver pSeries 690 Service Guide...
Страница 1123: ...Appendix E Ground Path The ground path for the pSeries 690 is shown in the following figure 1107...
Страница 1124: ...1108 Eserver pSeries 690 Service Guide...
Страница 1132: ...1116 Eserver pSeries 690 Service Guide...
Страница 1133: ......
Страница 1134: ...Printed in U S A February 2004 SA38 0589 05...