Error
Code
Description
Action/
Possible
Failing
FRU
20FF00A0
Invalid
VPD
(getvpd
mailbox
command
failed)
1.
Replace
the
part
specified
by
the
location
code.
2.
If
no
location
code
is
shown
with
the
error
code,
call
service
support.
20FF00B0
Invalid
VPD
(the
FG
keyword
is
not
found
for
a
fabric
card)
1.
Replace
the
part
specified
by
the
location
code.
2.
If
no
location
code
is
shown
with
the
error
code,
call
service
support.
20FF00B1
Invalid
VPD
(cannot
find
RM
keyword)
1.
Replace
the
part
specified
by
the
location
code.
2.
If
no
location
code
is
shown
with
the
error
code,
call
service
support.
20FF00C0
Invalid
VPD
(missing
base
address
of
the
RIO-PCI
bridge)
1.
Replace
the
part
specified
by
the
location
code.
2.
If
no
location
code
is
shown
with
the
error
code,
call
service
support.
20FF00D0
Invalid
VPD
(machine
type
field
is
invalid)
1.
Replace
the
part
specified
by
the
location
code.
2.
If
no
location
code
is
shown
with
the
error
code,
call
service
support.
20FF00F0
Invalid
VPD
(the
rack
number
and
the
unit
number
are
not
found
in
the
SCF
partition
in
NVRAM)
1.
Replace
the
part
specified
by
the
location
code.
2.
If
no
location
code
is
shown
with
the
error
code,
call
service
support.
2100
0xxx
SCSI
controller
fault
Before
replacing
any
system
components,
refer
to
the
notes
in
error
code
21A0
0001.
1.
Replace
the
SCSI
device.
21A0
0001
SCSI
DASD:
test
unit
ready
failed;
hardware
error
Before
replacing
any
system
components:
1.
Ensure
that
the
controller
and
each
device
on
the
SCSI
bus
is
assigned
a
unique
SCSI
ID.
2.
Ensure
that
the
SCSI
bus
is
properly
terminated.
3.
Ensure
that
the
SCSI
signal
and
power
cables
are
securely
connected
and
not
damaged.
The
location
code
information
is
required
to
identify
the
ID
of
SCSI
device
failures
as
well
as
to
indicate
the
location
of
the
controller
to
which
the
device
is
attached.
Check
the
system
error
logs
to
determine
the
location
code
information
associated
with
the
error
code.
1.
Replace
the
SCSI
device.
2.
Replace
the
SCSI
cable.
3.
Replace
the
SCSI
controller.
504
Eserver
pSeries
690
Service
Guide
Содержание eserver pSeries 690
Страница 1: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Страница 2: ......
Страница 3: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Страница 12: ...x Eserver pSeries 690 Service Guide...
Страница 14: ...xii Eserver pSeries 690 Service Guide...
Страница 228: ...Step 1527 5 Call your next level of support 212 Eserver pSeries 690 Service Guide...
Страница 357: ...Step 1543 15 Call for support This ends the procedure Chapter 3 Maintenance Analysis Procedures 341...
Страница 362: ...Step 1545 15 Call for support This ends the procedure 346 Eserver pSeries 690 Service Guide...
Страница 365: ...Step 1546 15 Call for support This ends the procedure Chapter 3 Maintenance Analysis Procedures 349...
Страница 381: ...Step 154A 14 Turn off the power Chapter 3 Maintenance Analysis Procedures 365...
Страница 430: ...414 Eserver pSeries 690 Service Guide...
Страница 798: ...782 Eserver pSeries 690 Service Guide...
Страница 868: ...Media Subsystem Internal Cables 1021 p690 Cable Installation and Management 1022 852 Eserver pSeries 690 Service Guide...
Страница 910: ...MCM Installation Shorts Test Step 3 See L3 Cache Modules on page 898 894 Eserver pSeries 690 Service Guide...
Страница 923: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 907...
Страница 924: ...L3 Cache Shorts Test Step 5 908 Eserver pSeries 690 Service Guide...
Страница 926: ...L3 Cache Shorts Test Step 2 910 Eserver pSeries 690 Service Guide...
Страница 928: ...L3 Cache Shorts Test Step 4 912 Eserver pSeries 690 Service Guide...
Страница 929: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 913...
Страница 1055: ...7040 Model 681 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 1039...
Страница 1057: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 1041...
Страница 1061: ...Power Cabling Chapter 10 Parts Information 1045...
Страница 1090: ...1074 Eserver pSeries 690 Service Guide...
Страница 1094: ...1078 Eserver pSeries 690 Service Guide...
Страница 1109: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations 1093...
Страница 1122: ...1106 Eserver pSeries 690 Service Guide...
Страница 1123: ...Appendix E Ground Path The ground path for the pSeries 690 is shown in the following figure 1107...
Страница 1124: ...1108 Eserver pSeries 690 Service Guide...
Страница 1132: ...1116 Eserver pSeries 690 Service Guide...
Страница 1133: ......
Страница 1134: ...Printed in U S A February 2004 SA38 0589 05...