A1D-04x
Description:
A
non-critical
error
has
been
detected,
an
internal
service
processor
memory
error.
Action:
Schedule
deferred
maintenance.
Use
A1D-05x
Description:
A
non-critical
error
has
been
detected,
a
service
processor
error
accessing
special
registers.
Action:
Schedule
deferred
maintenance.
Use
A1D-06x
Description:
A
non-critical
error
has
been
detected,
a
service
processor
reports
unknown
communication
error.
Action:
Schedule
deferred
maintenance.
Use
A1D-07x
Description:
A
non-critical
error
has
been
detected,:
Internal
service
processor
firmware
error
or
incorrect
version.
Action:
Schedule
deferred
maintenance.
Use
A1D-08x
Description:
A
non-critical
error
has
been
detected,
an
other
internal
service
processor
hardware
error.
Action:
Schedule
deferred
maintenance.
Use
A1D-09x
Description:
A
non-critical
error
has
been
detected,
a
service
processor
error
accessing
vital
product
data
EEPROM.
Action:
Schedule
deferred
maintenance.
Use
A1D-10x
Description:
A
non-critical
error
has
been
detected,
a
service
processor
error
accessing
operator
panel.
Action:
Schedule
deferred
maintenance.
Use
A1D-11x
Description:
A
non-critical
error
has
been
detected,
a
service
processor
error
accessing
power
controller.
Action:
Schedule
deferred
maintenance.
Use
A1D-12x
Description:
A
non-critical
error
has
been
detected,
a
service
processor
error
accessing
fan
sensor.
Action:
Schedule
deferred
maintenance.
Use
A1D-13x
Description:
A
non-critical
error
has
been
detected,
a
service
processor
error
accessing
a
thermal
sensor.
Action:
Schedule
deferred
maintenance.
Use
A1D-14x
Description:
A
non-critical
error
has
been
detected,
a
service
processor
error
accessing
voltage
sensor.
Action:
Schedule
deferred
maintenance.
Use
A1D-17x
Description:
A
non-critical
error
has
been
detected,
a
service
processor
error
accessing
serial
port.
Action:
Schedule
deferred
maintenance.
Use
A1D-18x
Description:
A
non-critical
error
has
been
detected,
a
service
processor
detected
NVRAM
error.
Action:
Schedule
deferred
maintenance.
Use
A1D-19x
Description:
A
non-critical
error
has
been
detected,
a
service
processor
error
accessing
real
time
clock/time-of-day
clock.
Action:
Schedule
deferred
maintenance.
Use
A1D-20x
Description:
A
non-critical
error
has
been
detected:
Service
processor
error
accessing
scan
controller/hardware.
Action:
Schedule
deferred
maintenance.
Use
A1D-21x
Description:
A
non-critical
error
has
been
detected,
a
service
processor
detected
error
with
time-of-day
clock
backup
battery.
Action:
Schedule
deferred
maintenance.
Use
1064
Eserver
pSeries
690
Service
Guide
Содержание eserver pSeries 690
Страница 1: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Страница 2: ......
Страница 3: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Страница 12: ...x Eserver pSeries 690 Service Guide...
Страница 14: ...xii Eserver pSeries 690 Service Guide...
Страница 228: ...Step 1527 5 Call your next level of support 212 Eserver pSeries 690 Service Guide...
Страница 357: ...Step 1543 15 Call for support This ends the procedure Chapter 3 Maintenance Analysis Procedures 341...
Страница 362: ...Step 1545 15 Call for support This ends the procedure 346 Eserver pSeries 690 Service Guide...
Страница 365: ...Step 1546 15 Call for support This ends the procedure Chapter 3 Maintenance Analysis Procedures 349...
Страница 381: ...Step 154A 14 Turn off the power Chapter 3 Maintenance Analysis Procedures 365...
Страница 430: ...414 Eserver pSeries 690 Service Guide...
Страница 798: ...782 Eserver pSeries 690 Service Guide...
Страница 868: ...Media Subsystem Internal Cables 1021 p690 Cable Installation and Management 1022 852 Eserver pSeries 690 Service Guide...
Страница 910: ...MCM Installation Shorts Test Step 3 See L3 Cache Modules on page 898 894 Eserver pSeries 690 Service Guide...
Страница 923: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 907...
Страница 924: ...L3 Cache Shorts Test Step 5 908 Eserver pSeries 690 Service Guide...
Страница 926: ...L3 Cache Shorts Test Step 2 910 Eserver pSeries 690 Service Guide...
Страница 928: ...L3 Cache Shorts Test Step 4 912 Eserver pSeries 690 Service Guide...
Страница 929: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 913...
Страница 1055: ...7040 Model 681 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 1039...
Страница 1057: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 1041...
Страница 1061: ...Power Cabling Chapter 10 Parts Information 1045...
Страница 1090: ...1074 Eserver pSeries 690 Service Guide...
Страница 1094: ...1078 Eserver pSeries 690 Service Guide...
Страница 1109: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations 1093...
Страница 1122: ...1106 Eserver pSeries 690 Service Guide...
Страница 1123: ...Appendix E Ground Path The ground path for the pSeries 690 is shown in the following figure 1107...
Страница 1124: ...1108 Eserver pSeries 690 Service Guide...
Страница 1132: ...1116 Eserver pSeries 690 Service Guide...
Страница 1133: ......
Страница 1134: ...Printed in U S A February 2004 SA38 0589 05...