1)
From the Tasks menu, click Properties.
2)
Click the Power-On Parameters tab.
3)
Set the Partition start policy field to the value that you recorded earlier.
4)
Click OK.
g.
To check for and handle new serviceable events that were generated during this procedure,
complete the following steps:
1)
In the navigation area, select Service Management.
2)
Select Manage Servicable Events.
3)
Specify event criteria that includes events that were generated during the procedure. In
particular, specify the managed system that the EMX0 PCIe3 expansion drawer was added to,
and specify a date and time range that includes the date and time that were recorded
previously.
4)
Perform problem analysis on any open serviceable events.
5)
Continue with step 8 on page 28.
6.
If you are using an HMC En Tech Preview (Pre-GA) or HMC E interface, complete
the following steps:
a.
In the navigation area, click the Resources icon
, and then select All Systems.
b.
In the content pane, select the name of the system to view the actions for that system.
c.
To enable the system to power on to the firmware standby state, complete the following steps:
1)
In the navigation area, select Properties > Other properties.
2)
Select the Power-On Parameters tab.
3)
Record the current setting for the Partition start policy field so that you can restore the setting
later in this procedure.
4)
Set the Partition start policy field to User-Initiated. Click OK.
d.
In the navigation area, select System Actions > Operations > Power on and click OK.
e.
In the content area, observe the system that you are working with until the value in the Status
column changes to Standby.
f.
To reset the Partition start policy field to its original value, complete the following steps:
1)
In the navigation area, select Properties > Other properties.
2)
Select the Power-On Parameters tab.
3)
Set the Partition start policy field to the value that you recorded earlier.
g.
To check for and handle new serviceable events that were generated during this procedure,
complete the following steps:
1)
In the navigation area, click the Serviceability icon, and then select Serviceable Events
Manager
.
2)
Specify event criteria that includes events that were generated during the procedure. In
particular, specify the managed system that the EMX0 PCIe3 expansion drawer was added to,
and specify a date and time range that includes the date and time that were recorded
previously.
3)
Perform problem analysis on any open serviceable events that are identified in the previous
step.
4)
Continue with step 8 on page 28.
7.
If you are using an ASMI, complete the following steps:
a.
In the ASMI navigation area, expand Power/Restart Control.
b.
Click Power On/Off System.
Installing an EMX0 PCIe Gen3 I/O expansion drawer
27
Содержание EMX0 PCIe3
Страница 1: ...Power Systems Installing the EMX0 PCIe Gen3 I O expansion drawer GI11 9914 04 IBM...
Страница 2: ......
Страница 3: ...Power Systems Installing the EMX0 PCIe Gen3 I O expansion drawer GI11 9914 04 IBM...
Страница 6: ...iv Power Systems Installing the EMX0 PCIe Gen3 I O expansion drawer...
Страница 16: ...xiv Power Systems Installing the EMX0 PCIe Gen3 I O expansion drawer...
Страница 58: ...42 Power Systems Installing the EMX0 PCIe Gen3 I O expansion drawer...
Страница 70: ...54 Power Systems Installing the EMX0 PCIe Gen3 I O expansion drawer...
Страница 71: ......
Страница 72: ...IBM Part Number 01LK530 Printed in USA GI11 9914 04 1P P N 01LK530...