Lit LED
Cause
Action
Minor system fault
(Amber)
When this LED is lit, the BladeCenter HT unit
has a minor system fault. The system can
continue to operate, usually without noticeable
loss of functionality or performance. The rear
panel minor alarm LED will be enabled and the
minor alarm relay will be activated.
Check the error log for the messages. Check
the LEDs on the BladeCenter HT unit and the
blade servers to isolate the component.
Media tray fault
(Amber)
Note:
The media
tray fault LED is
located on the
media tray on the
front of the
BladeCenter HT
unit.
There is an error with the media tray.
1. Reseat the media tray (see “Removing a
2. Replace the media tray.
Alarm panel
module fault
(Amber)
Note:
The alarm
panel module fault
LED is located on
the alarm panel
module on the rear
of the BladeCenter
HT unit.
There is an error with the alarm panel module.
1. Reseat the alarm panel module (see
“Removing an alarm panel module” on
page 81.)
2. Replace the alarm panel module.
114
BladeCenter HT Type 8740 and 8750: Problem Determination and Service Guide
Содержание BladeCenter HT 8740
Страница 1: ...BladeCenter HT Type 8740 and 8750 Problem Determination and Service Guide ...
Страница 2: ......
Страница 3: ...BladeCenter HT Type 8740 and 8750 Problem Determination and Service Guide ...
Страница 8: ...vi BladeCenter HT Type 8740 and 8750 Problem Determination and Service Guide ...
Страница 48: ...30 BladeCenter HT Type 8740 and 8750 Problem Determination and Service Guide ...
Страница 118: ...100 BladeCenter HT Type 8740 and 8750 Problem Determination and Service Guide ...
Страница 142: ...124 BladeCenter HT Type 8740 and 8750 Problem Determination and Service Guide ...
Страница 150: ...132 BladeCenter HT Type 8740 and 8750 Problem Determination and Service Guide ...
Страница 156: ...138 BladeCenter HT Type 8740 and 8750 Problem Determination and Service Guide ...
Страница 157: ......
Страница 158: ... Part Number 00V9904 Printed in USA 1P P N 00V9904 ...