For more information on the Automatic Dialout Settings
window, see “Automatic Dialout Settings” on page 60.
Loader Timeout:
The Loader timeout field shows the
number of seconds that the system management
subsystem will wait for the system's loading process to
complete before generating a Loader Timeout event. The
Loader Timeout measures the amount of time that passes
between the completion of POST and the end of operating
system (O/S) startup. If this takes longer than the
configured amount of time to complete and the Loader
timeout check box (found in the Enabled Alerts Dialout
group of the Automatic Dialout Settings window) is
checked, the system management subsystem will
automatically restart the system one time and will attempt
to forward an alert to all enabled Dialout Entries. Once the
system is restarted, Loader timeout is automatically
disabled.
To set the Loader timeout value, use the spin buttons
beside the Loader timeout field to set the number of
seconds that the system management subsystem will wait
between POST completion and O/S startup before
generating a timeout event. Then, click on Apply to save
this value.
For more information on the Automatic Dialout Settings
window, see “Automatic Dialout Settings” on page 60.
O/S Timeout:
A periodic signal is sent from the
Netfinity Advanced System Management PCI Adapter to
the O/S to confirm that the O/S is running properly. The
O/S Timeout event occurs when the O/S the Netfinity
Advanced System Management PCI Adapter performs its
automatic dialout functions if there is no response to the
signal; that is, if the O/S Timeout pulse is not detected.
The O/S timeout field shows the number of seconds that
the system management subsystem will wait for the
system's operating system to respond before generating
an O/S Timeout event. If the O/S takes longer than the
configured amount of time to respond and the device driver
is installed and running correctly, the system management
subsystem will attempt to restart the system, and if the O/S
timeout check box (found in the Enabled Alerts Dialout
group of the Automatic Dialout Settings window) is
checked, the system management subsystem will
automatically restart the system one time and will attempt
to forward an alert to all enabled Dialout Entries.
To set the O/S timeout value, use the spin buttons beside
the O/S timeout field to set the number of seconds that
the system management subsystem will wait for the
system's operating system to respond before generating
an O/S Timeout event. Then, click on Apply to save this
value.
Netfinity 7000-M10 - Type 8680
53
Содержание 86803RU - Netfinity 7000 M10
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 110: ...1 5 6 9 102 Netfinity Server HMM...
Страница 232: ...224 Netfinity Server HMM...
Страница 249: ...Related Service Information 241...
Страница 250: ...242 Netfinity Server HMM...
Страница 251: ...Related Service Information 243...
Страница 252: ...244 Netfinity Server HMM...
Страница 253: ...Related Service Information 245...
Страница 266: ...258 Netfinity Server HMM...
Страница 267: ...Related Service Information 259...
Страница 268: ...260 Netfinity Server HMM...
Страница 278: ...IBM Part Number 09N1052 Printed in U S A S 1K 4643 2...