6. Push the slide-bracket assemblies to the outermost
positions on the rack.
7. Tighten all screws to secure both slide-bracket
assemblies. If you are using a torque screwdriver,
use the following torque setting:
8–11 Nm (70.8–97.0 in/lbs).
8. Attach the cable-management arm to the rear of the
rack:
a. Position the cable-management arm bracket on
the outside of the mounting rail.
b. Insert two screws (M6 by 16 mm) through the
cable-management arm bracket, mounting rail,
and cage nuts. Tighten the screws.
c. Position the server bracket on the
cable-management arm.
128