Installing a Non-Hot-Plug PCI Adapter:
This
section gives the procedures for installing a non-hot-plug
adapter. If you want to remove a non-hot-plug adapter,
reverse the steps.
Before you begin:
Read “Safety Information” on page 226.
Read the documentation that comes with your
adapter for any special requirements or
restrictions.
Refer to the illustrations in “Installing a Hot-Plug PCI
Adapter” on page 176 while you perform the steps in this
procedure.
To install a non-hot-plug PCI adapter:
1. Run the shutdown procedure for the operating
system. Turn off the server and peripheral devices
and disconnect all external cables and power cords
(see “Preparing to Install Options” on page 160); then
remove the top cover (see “Removing the Top Cover”
on page 161).
2. Determine which expansion slot you will use for the
adapter.
Note
Check the instructions that come with the adapter
for any requirements or restrictions.
3. Remove the expansion-slot cover
.3/
:
a. See the illustrations in “Installing a Hot-Plug PCI
Adapter” on page 176 for operation of the
adapter retention latch on the end of the slot
near the rear of the server.
b. Rotate the adapter retention latch
.2/
.
c. Lift the tab
.1/
covering the top of the
expansion-slot cover and remove the
expansion-slot cover from the server. Store it in
a safe place for future use.
Attention: Expansion-slot covers must be
installed on all vacant slots. This maintains the
electromagnetic-emissions characteristics of the
system and ensures proper cooling of system
components.
4. Refer to the documentation that comes with your
adapter for any cabling instructions. It might be
easier for you to route any cables before you install
the adapter.
5. Remove the adapter from the static-protective
package.
180
Netfinity Server HMM
Содержание 86803RU - Netfinity 7000 M10
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 110: ...1 5 6 9 102 Netfinity Server HMM...
Страница 232: ...224 Netfinity Server HMM...
Страница 249: ...Related Service Information 241...
Страница 250: ...242 Netfinity Server HMM...
Страница 251: ...Related Service Information 243...
Страница 252: ...244 Netfinity Server HMM...
Страница 253: ...Related Service Information 245...
Страница 266: ...258 Netfinity Server HMM...
Страница 267: ...Related Service Information 259...
Страница 268: ...260 Netfinity Server HMM...
Страница 278: ...IBM Part Number 09N1052 Printed in U S A S 1K 4643 2...