System reliability guidelines
To help ensure proper cooling and system reliability, make sure that the following
requirements are met:
v
The CD or DVD drive tray has a drive or a filler panel and electromagnetic
compatibility (EMC) shield installed in it.
v
There is adequate space around the server to allow the server cooling system to
work properly. Leave approximately 50 mm (2 in.) of open space around the front
and rear of the server. Do not place objects in front of the fans. For proper
cooling and airflow, replace the server cover before turning on the server.
Operating the server for extended periods of time (more than 30 minutes) with
the server cover removed might damage server components.
v
You have followed the cabling instructions that come with optional adapters.
v
You have replaced a failed fan as soon as possible.
v
You have kept the preinstalled air deflector in place unless you are directed to
remove it in this document or by IBM Service. See “Removing an air baffle” on
page 32 for the location of the air deflector in the server.
Handling static-sensitive devices
Attention:
Static electricity can damage the server and other electronic devices.
To avoid damage, keep static-sensitive devices in their static-protective packages
until you are ready to install them.
To reduce the possibility of damage from electrostatic discharge, observe the
following precautions:
v
Limit your movement. Movement can cause static electricity to build up around
you.
v
The use of a grounding system is recommended. For example, wear an
electrostatic-discharge wrist strap, if one is available. Always use an
electrostatic-discharge wrist strap or other grounding system when you work
inside the server with the power on.
v
Handle the device carefully, holding it by its edges or its frame.
v
Do not touch solder joints, pins, or exposed circuitry.
v
Do not leave the device where others can handle and damage it.
v
While the device is still in its static-protective package, touch it to an unpainted
metal part on the outside of the server for at least 2 seconds. This drains static
electricity from the package and from your body.
v
Remove the device from its package and install it directly into the server without
setting down the device. If it is necessary to set down the device, put it back into
its static-protective package. Do not place the device on the server cover or on a
metal surface.
v
Take additional care when handling devices during cold weather. Heating reduces
indoor humidity and increases static electricity.
Returning a device or component
If you are instructed to return a device or component, follow all packaging
instructions, and use any packaging materials for shipping that are supplied to you.
30
IBM System x3455 Type 7940 and 7941: Problem Determination and Service Guide
Содержание 7940
Страница 1: ...IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 2: ......
Страница 3: ...IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 8: ...vi IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 18: ...xvi IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 32: ...14 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 36: ...18 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 46: ...28 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 142: ...124 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 152: ...134 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 158: ...140 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 159: ......
Страница 160: ... Part Number 49Y0088 Printed in USA 1P P N 49Y0088 ...