Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Type 7940 and 7941 servers,” on page 19 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
BMC log message
Sensor
type
Sensor
number
Action
CPU 1 Presense Detected Deasserte
CPU 2 Presense Detected Deasserted
07h
07h
90h
91h
Trained service technician only:
1. Reseat CPU n.
2. Replace CPU n.
3. Replace the system board.
CPU 1 Disabled Asserted
CPU 2 Disabled Asserted
07h
07h
90h
91h
Trained service technician only:
1. Reseat CPU n.
2. Replace CPU n.
3. Replace the system board.
CPU 1 Disabled Deasserted
CPU 2 Disabled Deasserted
07h
07h
90h
91h
Information only
CPU 1 Bad VID Asserted
CPU 2 Bad VID Asserted
07h
07h
9Ch
9Dh
Trained service technician only:
1. Reseat CPU n.
2. Replace CPU n.
3. Replace the system board.
CPU 1 Bad VID Deasserted
CPU 2 Bad VID Deasserted
07h
07h
9Ch
9Dh
Information only
VRD 1 Presense Detected Asserted
VRD 2 Presense Detected Asserted
08h
08h
24h
25h
Information only
VRD 1 Power Supply Failure Asserted
VRD 2 Power Supply Failure Asserted
VRD 2.5V Power Supply Failuer Asserted
VRD 1.8V Power Supply Failure Asserted
VRD 1.2V Power Supply Failure Asserted
08h
08h
08h
08h
08h
24h
25h
2Ah
2Dh
2Fh
Trained service technician only:
1. Replace the power supply.
2. Reseat CPU n.
3. Replace CPU n.
4. Replace the system board.
HTX Syncflood Asserted
PCI-E x16 Syncflood Asserted
PCI-E x8 Syncflood Asserted
21h
21h
21h
ABh
ABh
ABh
1. Remove Adaptors cards.
2. Replace Adaptor cards one at a time to
isolate error.
3. (Trained service technician only) Replace
system board.
Onboard Device Syncflood Asserted
HT1000 Legacy I/O Syncflood Asserted
System Reset Due to Unrecoverable Error
I/O Subsystem Timeout Asserted
PCI-E x16 Timeout Asserted
PCI-E x8 Timeout Asserted
21h
21h
21h
21h
21h
21h
ACh
ACh
ACh
ACh
ACh
ACh
1. Remove Adaptors cards.
2. Replace Adaptor cards one at a time to
isolate error.
3. (Trained service technician only) Replace
system board.
Power Supply Failure Asserted
08h
70h
Trained service technician only:
1. Replace the power supply.
2. Replace the system board.
Power Supply EPOW Asserted
08h
70h
Information only
Power Supply EPOW Deasserted
08h
70h
Information only
Chapter 5. Diagnostics
113
Содержание 7940
Страница 1: ...IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 2: ......
Страница 3: ...IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 8: ...vi IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 18: ...xvi IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 32: ...14 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 36: ...18 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 46: ...28 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 142: ...124 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 152: ...134 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 158: ...140 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 159: ......
Страница 160: ... Part Number 49Y0088 Printed in USA 1P P N 49Y0088 ...