v
Power cord
v
Three cooling fans
The following illustration shows the locations of the power-supply LEDs.
USB connectors (4)
Ethernet
connectors
(2)
LAN activity LED
Link LED
Video
connector
Power-cord
connector
Serial connector
AC power LED
DC power LED
System locator LED
NMI switch
The following table describes the problems that are indicated by various
combinations of the power-supply LEDs and the power-on LED on the operator
information panel and suggested actions to correct the detected problems.
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Type 7940 and 7941 servers,” on page 19 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Power-supply
LEDs
Operator
information
panel
power-on
LED
Description
Action
AC
DC
Off
Off
Off
No power to the
server, or a problem
with the ac power
source.
1. Check the ac power to the server.
2. Make sure that the ac power cord is connected to a
functioning power source.
Lit
Off
Off
DC source power
problem.
1. View the BMC system event log (see “Error logs” on
page 76).
2. Replace the power supply (see “Removing the power
supply” on page 46).
3. (Trained service technician only) Replace the system
board (see “Removing the system board” on page
64).
Lit
Lit
Off
Standby power
problem.
1. Reseat the operator information panel signal cable.
2. Replace the operator information panel signal cable.
3. Replace the operator information panel (see
“Removing the operator information panel” on page
49).
4. (Trained service technician only) Replace the system
board (see “Removing the system board” on page
64).
Lit
Lit
Flashing
The power is good.
The server is not powered on. No action is necessary.
Lit
Lit
Lit
The power is good.
The server is powered on. No action is necessary.
100
IBM System x3455 Type 7940 and 7941: Problem Determination and Service Guide
Содержание 7940
Страница 1: ...IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 2: ......
Страница 3: ...IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 8: ...vi IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 18: ...xvi IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 32: ...14 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 36: ...18 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 46: ...28 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 142: ...124 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 152: ...134 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 158: ...140 IBM System x3455 Type 7940 and 7941 Problem Determination and Service Guide ...
Страница 159: ......
Страница 160: ... Part Number 49Y0088 Printed in USA 1P P N 49Y0088 ...