Chapter 4. Physical Characteristics of Displays
This chapter provides the physical characteristics for some of the displays that can be used with the
systems. The following information can help you plan for your displays. You need only do physical
planning for the displays you have ordered.
POWERdisplay 17 and POWERdisplay 20
POWERdisplay 17 with a maximum viewable image size of 409 mm (16.1 inches) measured diagonally.
POWERdisplay 20 with a maximum viewable image size of 486 mm (19.1 inches) measured diagonally
Dimensions
POWERdisplay 17
Height
414 mm
16.3 in
Width
404 mm
15.9 in
Depth
450 mm
17.7 in
POWERdisplay 20
Height
474 mm
18.6 in
Width
480 mm
18.9 in
Depth
505 mm
19.9 in
Weight
POWERdisplay 17
22.5 kg
49.5 lbs
POWERdisplay 20
30.0 kg
66.3 lbs
Electrical
Power source loading
.38
(typical in kVA)
Voltage range (V ac)
100 to 120 or 200 to 240 (autoranging)
Frequency (hertz)
50 or 60
Thermal output
(typical)
480 Btu/hr
Power requirements
(typical)
140 watts
Power factor
0.7
Maximum altitude
3048 m (10,000 ft.)
Temperature
Requirements
Operating
10 to 40°C
(50 to 104°F)
Non-Operating
1 to 60°C
(35 to 140°F)
Humidity
Requirements
Operating
Non-Operating
(Noncondensing)
8 to 80 %
8 to 80 %
Noise Emissions*
Operating
Idle
L
WAd
3.5 bels
3.5 bels
Clearances
Front
Back
Left
Right
Service
Install so that air vents are not blocked.
* See “Noise Emission Notes” on page 336 for definitions of noise emissions positions.
221
Содержание 7012 397
Страница 1: ...RS 6000 and Eserver pSeries Site and Hardware Planning Information SA38 0508 20...
Страница 2: ......
Страница 3: ...RS 6000 and Eserver pSeries Site and Hardware Planning Information SA38 0508 20...
Страница 11: ...Appendix Notices 385 Index 387 Contents ix...
Страница 12: ...x Site and Hardware Planning Information...
Страница 16: ...xiv Site and Hardware Planning Information...
Страница 18: ...xvi Site and Hardware Planning Information...
Страница 26: ...8 Site and Hardware Planning Information...
Страница 238: ...220 Site and Hardware Planning Information...
Страница 246: ...228 Site and Hardware Planning Information...
Страница 284: ...266 Site and Hardware Planning Information...
Страница 296: ...278 Site and Hardware Planning Information...
Страница 366: ...348 Site and Hardware Planning Information...
Страница 372: ...Async Adapter Cable Planning Chart 354 Site and Hardware Planning Information...
Страница 374: ...128 Port Async Controller Cable Planning Chart Controller Line Interface 356 Site and Hardware Planning Information...
Страница 377: ...Standard I O Cable Planning Chart Chapter 12 Cable Planning 359...
Страница 380: ...Cable Planning Chart Other Adapters 362 Site and Hardware Planning Information...
Страница 382: ...7318 Serial Communications Network Server Cable Planning Chart 364 Site and Hardware Planning Information...
Страница 384: ...366 Site and Hardware Planning Information...
Страница 402: ...384 Site and Hardware Planning Information...
Страница 404: ...386 Site and Hardware Planning Information...
Страница 413: ......
Страница 414: ...Printed in USA SA38 0508 20...
Страница 415: ...Spine information RS 6000 and Eserver pSeries Site and Hardware Planning Information...