Chapter 6: Twinax Client Cabling Requirements and Problem Solving
92 Planning, Installation, and Maintenance Guide
Another OEM power monitor provides 8-channel digital storage of external
voltage waveforms. The recorded waveforms may be displayed on a screen.
The recording is triggered when a disturbance occurs that exceeds a
predefined limit.
Wire Resistance
Wire resistance measurements indicate the presence of opens, shorts, faults,
high-resistance connections, or incorrect wire sizes. Opens, shorts, or faults
usually cause an inoperative network. High-resistance connections or
incorrect wire sizes can cause:
• High error rates
• An inoperative network or attached device
Small wire size can limit the drive capability below the allowable distance
specified.
Measured Wire Resistance Length versus Electrical Length
Comparing the wire length determined by a resistance measurement to the
length measured by a time domain reflectometer can determine whether
different sizes of wire exist in the loop (that is, whether the wiring in the
building is consistent). See “Advanced Time Domain Relfectometry (TDR)
Procedure” on page 113. Do not use loops that contain different sizes of wire
for 5250 protocol transmission.
Wire length that exceeds the specified limits can cause:
• Excessive errors or intermittent errors
• An inoperative network or attached device
Characteristic Impedance
Wire whose characteristic impedance exceeds the specified limits might not
be suitable for high-speed data transmission. Increased error rates can result
from the use of such wire.
Impedance Discontinuities
Impedance discontinuities can be caused by any of the following that exist
along the wire path:
Opens
Shorts
Loose connections
Wiring stubs
Bridge taps
Loading circuits
Telephone jacks
Connector blocks
Excessive impedance discontinuities can cause:
Reflections that can increase the error rate
Содержание 5500-01E
Страница 1: ...S05J 4934 00 5500 Express IP Control Unit Planning Installation and Maintenance Guide...
Страница 2: ......
Страница 3: ...S05J 4934 00 5500 Express IP Control Unit Planning Installation and Maintenance Guide...
Страница 16: ...xvi Planning Installation and Maintenance Guide...
Страница 30: ...Chapter 1 Introducing the IBM 5500 Express IP Control Unit 30 Planning Installation and Maintenance Guide...
Страница 48: ...Chapter 2 Planning Your Installation 48 Planning Installation and Maintenance Guide...
Страница 54: ...Chapter 3 Installing the 5500 Express IP Control Unit 54 Planning Installation and Maintenance Guide...
Страница 68: ...Chapter 4 Configuring the 5500 Express IP Control Unit 68 Planning Installation and Maintenance Guide...
Страница 144: ...144 Planning Installation and Maintenance Guide...
Страница 145: ...Appendix A 145...
Страница 146: ...146 Planning Installation and Maintenance Guide...
Страница 147: ...Appendix A 147...
Страница 148: ...148 Planning Installation and Maintenance Guide...
Страница 149: ...Appendix A 149...
Страница 150: ...150 Planning Installation and Maintenance Guide...
Страница 151: ...Appendix A 151...
Страница 152: ...152 Planning Installation and Maintenance Guide...
Страница 153: ...Appendix A 153...
Страница 154: ...154 Planning Installation and Maintenance Guide...
Страница 155: ...Appendix A 155...
Страница 156: ...156 Planning Installation and Maintenance Guide...
Страница 157: ...Appendix A 157...
Страница 158: ...158 Planning Installation and Maintenance Guide...
Страница 164: ...164 Planning Installation and Maintenance...
Страница 184: ...Glossary 184...
Страница 188: ...Index 4...
Страница 191: ......