Removing and replacing Tier 2 CRUs
You may install a Tier 2 CRU yourself or request IBM to install it, at no additional
charge, under the type of warranty service that is designated for the server.
The illustrations in this document might differ slightly from your hardware.
Removing the battery
To remove the battery, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 47.
2. Turn off the server and all attached devices; then, disconnect all power cords
and external cables.
3. Unlock and remove the side cover (see “Removing the side cover” on page 52).
4. Remove any adapters that impede access to the battery.
5. Locate the battery on the system board (see “System-board internal connectors”
on page 9).
6. Remove the battery:
a. Use a fingernail to press the top of the battery clip away from the battery.
The battery pops up when it is released.
b. Use your thumb and index finger to lift the battery from the socket.
Installing the battery
The following notes describe information that you must consider when you replace
the battery in the server.
v
You must replace the battery with a lithium battery of the same type from the
same manufacturer.
v
To order replacement batteries, call 1-800-426-7378 within the United States, and
1-800-465-7999 or 1-800-465-6666 within Canada. Outside the U.S. and
Canada, call your IBM marketing representative or authorized reseller.
v
After you replace the battery, you must reconfigure the server and reset the
system date and time.
v
To avoid possible danger, read and follow the following safety statement.
Chapter 4. Removing and replacing server components
77
Содержание 436854u - System x3200 M2 5U Mini Tower...
Страница 1: ...System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 32: ...14 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 50: ...32 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 64: ...46 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 138: ...120 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 258: ...240 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...Part Number 49Y0163 Printed in USA 1P P N 49Y0163...