Table 9. DSA diagnostic messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 3, “Parts listing, System x3200 M2 Types 4367 and 4368,” on page 33 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained
service technician.
Message
number
Component
Test
State
Description
Action
201-902-xxx
Memory
Memory Test
Failed
Test failure:
single-bit and
multi-bit error,
failing bank x,
failing DIMM z
1. Turn off the system and disconnect it
from the power source.
2. Reseat DIMM z.
3. Reconnect the system to the power
source and turn on the system.
4. Make sure that the DSA code is at the
latest level. For the latest level of DSA
code, go to http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
DSA.
5. Make sure that the BIOS code is at
the latest level. The installed firmware
level is shown in the DSA event log in
the Firmware/VPD section for this
component. For the latest level of
firmware, go to http://www.ibm.com/
support/docview.wss?uid=psg1
MIGR-4JTS2T and select your system
to display a matrix of available
firmware.
6. Run the test again.
7. Replace the failing DIMMs.
8. Re-enable all memory in the
Configuration/Setup Utility program
(press F1 at system startup).
9. Run the test again.
10. Replace the failing DIMMs.
11. Re-enable all memory in the
Configuration/Setup Utility program
(press F1 at system startup).
12. Run the test again.
13. If the problem remains, collect the
data from the DSA event log and send
it to IBM Service. For information
about contacting and sending data to
IBM Service, see
http://www.ibm.com/support/
docview.wss?uid=psg1SERV-CALL.
Chapter 5. Diagnostics
203
Содержание 436854u - System x3200 M2 5U Mini Tower...
Страница 1: ...System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 32: ...14 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 50: ...32 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 64: ...46 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 138: ...120 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 258: ...240 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...Part Number 49Y0163 Printed in USA 1P P N 49Y0163...