Removing the rear system fan
Attention:
v
Replace a failed fan within 48 hours.
v
To ensure proper cooling and airflow, do not operate the server for more than 30
minutes with the side cover removed.
To remove the rear system fan, complete the following steps:
1. Turn off the server and all attached devices; then, disconnect all power cords
and external cables.
2. Unlock and remove the side cover (see “Removing the side cover” on page 52).
3. Remove any adapters that impede access to the fan and the fan connector on
the system board (see “Removing an adapter” on page 58).
4. Disconnect the fan cable from the system board, making a note of where the
cable was connected, for later installation.
5. Grasp the fan with both hands and pull firmly, extending the rubber grommets.
The grommets will be pulled through the holes in either the fan or the chassis
and can then be removed.
Rubber
grommets
Rear system
Fan
6. Pull the fan up and out of the chassis.
7. If you are instructed to return the fan, follow all packaging instructions, and use
any packaging materials for shipping that are supplied to you.
Chapter 4. Removing and replacing server components
79
Содержание 436854u - System x3200 M2 5U Mini Tower...
Страница 1: ...System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 32: ...14 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 50: ...32 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 64: ...46 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 138: ...120 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 258: ...240 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...Part Number 49Y0163 Printed in USA 1P P N 49Y0163...