The following table describes the problems that are indicated by various
combinations of the power-supply LEDs and the power-on LED on the front
information panel and suggested actions to correct the detected problems.
v
Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
v
See Chapter 3, “Parts listing, System x3200 M2 Types 4367 and 4368,” on page 33
to determine which components are customer replaceable units (CRU) and which
components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must
be performed only by a trained service technician.
Power-supply
LEDs
Front
information
panel power-on
LED
Description
Action
AC
DC
Off
Off
Off
No power to the
server, or a
problem with the
ac power source.
1. Check the ac power to the server.
2. Make sure that the power cord is
connected to a functioning power
source.
3. Remove one power supply at a
time.
Lit
Off
Off
DC source or
power supply
power problem.
1. Make sure that the power supply is
connected to the power backplane.
2. Remove and replace one power
supply at a time.
3. View the system-error log (see
“Error logs” on page 125).
Lit
Lit
Off
Standby power
problem.
1. View the system-error log (see
“Error logs” on page 125).
2. Remove one power supply at a
time.
3. (Trained service technician only)
Replace the power backplane.
Lit
Lit
Flashing
System
power-on
problem.
1. View the system-error log (see
“Error logs” on page 125).
2. Make sure that the power cables
are seated correctly.
3. Press the power-control button on
the control-panel.
4. Remove the optional Remote
Supervisor Adapter II SlimLine, and
try to turn on the server.
5. (Trained service technician only)
Reseat the system board.
6. (Trained service technician only)
Replace the system board.
Lit
Lit
Lit
The power is
good.
No action is necessary.
154
System x3200 M2 Types 4367 and 4368: Problem Determination and Service Guide
Содержание 436854u - System x3200 M2 5U Mini Tower...
Страница 1: ...System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 32: ...14 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 50: ...32 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 64: ...46 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 138: ...120 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 258: ...240 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide...
Страница 265: ......
Страница 266: ...Part Number 49Y0163 Printed in USA 1P P N 49Y0163...