background image

Hitachi Advanced Server DS7000

 

Description Guide

 

This document describes the Hitachi Advanced Server DS7000 documentation and 

gives an overview of the server.

MK-97HAS7015

-0

4

 

November 

2021 

Summary of Contents for DS7000 Series

Page 1: ...Hitachi Advanced Server DS7000 Description Guide This document describes the Hitachi Advanced Server DS7000 documentation and gives an overview of the server MK 97HAS7015 04 November 2021 ...

Page 2: ...tice on Export Controls The technical data and technology inherent in this Document may be subject to U S export control laws including the U S Export Administration Act and its associated regulations and may be subject to export or import regulations in other countries Reader agrees to comply strictly with all such regulations and acknowledges that Reader has the responsibility to obtain licenses...

Page 3: ... CANADA p 3 VCCI Certification Japan p 3 Waste Management p 3 REACH p 3 ROHS p 3 WEEE p 3 Safety Notices p 4 Chapter 1 Related Publications 1 1 Chapter 2 Hitachi Advanced Server DS7000 Series Overview 2 1 2 1 Overview 2 1 2 2 Hitachi Advanced Server DS7000 Series 2 2 2 2 1 Hitachi Advanced Server DS7020 2 2 2 2 2 Hitachi Advanced Server DS7040 2 3 2 2 3 Hitachi Advanced Server DS7080 2 4 2 2 4 Hit...

Page 4: ...6 5 3 3 Disk Numbering 5 7 5 3 4 Fan Box Numbering 5 9 5 4 3 5 SAS Disks Storage Unit 5 10 5 4 1 Components 5 10 5 4 2 SBB Positions 5 11 5 4 3 Disk Numbering 5 12 5 4 4 Fan Box Numbering 5 13 5 5 NVMe Disks Storage Unit 5 14 5 5 1 Components 5 14 5 5 2 NBB Positions 5 15 5 5 3 Disk Numbering 5 16 5 5 4 Fan Box Numbering 5 17 Chapter 6 UBox Components 6 1 6 1 Components 6 1 6 2 Numbering 6 3 6 2 1...

Page 5: ...14 7 3 Internal LEDs 7 15 7 3 1 2 5 SAS Disks Storage Unit 7 15 7 3 2 3 5 SAS Disks Storage Unit 7 16 7 3 3 NVMe Disks Storage Unit 7 17 7 4 Ports 7 18 Appendix A Technical Description A 1 A 1 General Technical Specifications A 1 A 2 Dimensions and Weights A 2 A 3 Module Technical Specifications A 3 A 4 UBox Technical Specifications A 4 A 5 Server Technical Description A 5 Acronyms a 1 ...

Page 6: ...irmware downloads are available on Hitachi Vantara Support Connect https support hitachivantara com Log in and select Product Downloads to access the most current downloads including updates that may have been made after the release of the product Getting Help Hitachi Vantara Support Connect is the destination for technical support of products and solutions sold by Hitachi Vantara To contact techn...

Page 7: ...ay cause undesired operation FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if n...

Page 8: ... protection requirements of the ICES 003 standard VCCI Certification Japan This equipment complies with the VCCI V 3 2008 4 requirements This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be req...

Page 9: ...presence of a hazard that has the potential of causing death or serious personal injury C0xx CAUTION C0xx A Caution notice indicates the presence of a hazard that has the potential of causing moderate or minor personal injury W0xx WARNING W0xx A Warning notice indicates an action that could cause damage to a program device system or data Each safety notices is prefixed with a unique identification...

Page 10: ...tall a Hitachi Advanced Server DS7000 in a rack cabinet Installation Hitachi Advanced Server DS7000 Installation Guide explains how to install the server for the first time This guide is intended for use by qualified personnel in charge of installing servers Hitachi Advanced Server DS7000 iCare Console Installation Guide explains how to install iCare to monitor and maintain servers This guide is i...

Page 11: ...intended for personnel in charge of maintaining the servers on the customer s site Hitachi Advanced Server DS7000 Field Service Guide explains how to replace Field Replaceable Units FRU This guide is intended for use by qualified personnel Hitachi Advanced Server DS7000 Customer Troubleshooting Guide explains how to troubleshoot the server Hitachi Advanced Server DS7000 Field Troubleshooting Guide...

Page 12: ...port up to twelve memory modules each It features five PCIe slots either five PCIex8 or two PCIex16 plus one PCIex8 The Hitachi Advanced Server DS7000 series offers a scalable DS7020 DS7040 or DS7080 glueless multi module server via an intermodule connecting box The Hitachi Advanced Server DS7080 can be upgraded to DS7160 using a UBox that houses the eXternal Node Controller XNC The Hitachi Advanc...

Page 13: ...2 Hitachi Advanced Server DS7000 Series 2 2 1 Hitachi Advanced Server DS7020 The Hitachi Advanced Server DS7020 is composed of One module One module connecting box Rear view Mark Description A Module connecting box B Module 0 ...

Page 14: ...vanced Server DS7040 is composed of Two modules One 2 module connecting box Rear view Mark Label A 2 sockets server2 module connecting box B Module 0 C Module 1 Note If the server is not fully populated with two modules a filler bezel can be inserted into the empty space See section 2 3 3 Filler Bezel for details ...

Page 15: ...composed of Four modules One 4 module connecting box Rear view Mark Label A 4 module connecting box B Module 0 C Module 1 D Module 2 E Module 3 Note If the server is not fully populated with four modules a filler bezel can be inserted into the empty space See section 2 3 3 Filler Bezel for details ...

Page 16: ...ries Overview 2 5 2 2 4 Hitachi Advanced Server DS7160 2 2 4 1 Overview The Hitachi Advanced Server DS7160 is composed of Two Hitachi Advanced Server DS7080 assemblies A The 8 module connecting box at the rear B The UBox at the front C Rear view ...

Page 17: ...2 6 Description Guide Exploded view Front view ...

Page 18: ...Chapter 2 Hitachi Advanced Server DS7000 Series Overview 2 7 2 2 4 2 Modules Numbering Rear view Mark Description A Module 0 B Module 1 C Module 2 D Module 3 E Module 4 F Module 5 G Module 6 H Module 7 ...

Page 19: ...zel and the main box at the front the Power Supply Units PSU the PCIe slots and the Intermodule connecting box at the rear All these components are included in the compute box Mark Description A Bezel B Main box C Compute Box D Power Supply Unit PSU E PCIe slots F Module connecting box ...

Page 20: ...Advanced Server DS7000 Series Overview 2 9 2 3 2 Main Box Overview The main box consists of a compute unit A and an optional unit B The optional unit may be equipped with a storage drawer C to support the storage options ...

Page 21: ... 10 Description Guide 2 3 3 Filler Bezel If the server is not fully populated with modules a filler bezel is inserted into the empty space It is attached to the front of the server by two captive screws ...

Page 22: ...chi Advanced Server DS7020 Rear view Mark Component A Identification drawer B Power Supply Unit PSU C Two PCI e x8 blades or one PCI e x16 blade D Phy Ethernet Board PEB or Phy Ethernet Board SFP PEBS E Module connecting box F PCI e x8 blade dedicated for RAID SAS controller ...

Page 23: ... Description A Power Supply Unit PSU B Identification drawer C Two PCI e x8 blades or one PCI e x16 blade D Phy Ethernet Board PEB or Phy Ethernet Board SFP PEBS E PCI e x8 blade dedicated for RAID SAS controller F 2 module connecting box G sWitch Ethernet One Gigabit WEO ...

Page 24: ...ew Mark Description A Identification drawer B Power Supply Unit PSU C Two PCI e x8 blades or one PCI e x16 blade D Phy Ethernet Board PEB or Phy Ethernet Board SFP PEBS E PCI e x8 blade dedicated for RAID SAS controller F 4 module connecting box G sWitch Ethernet One Gigabit WEO ...

Page 25: ...3 4 Description Guide 3 4 Power Supply Units PSU Each module is equipped with two PSU 1 1 redundancy Rear view Mark Description A PSU 1 B PSU 0 ...

Page 26: ...nents 4 1 Chapter 4 Compute Unit Components 4 1 Components Front view Mark Description Quantity A CPU Purley Board CPB Motherboard 1 B Front Disk Blades FDB 4 C Management Board Left Side MLB 1 D Management Board Right Side MRB 1 ...

Page 27: ... Description Guide 4 2 CPU Purley Board CPB Motherboard Top view Mark Description Quantity A Memory modules 24 B Processor Assembly CPU 2 C PCIe slots 5 D UPI slot 1 E PCIe connectors 2 F FDB Connectors 4 ...

Page 28: ...Chapter 4 Compute Unit Components 4 3 4 3 Processor Assembly CPU Top view Mark Description A CPU 0 B CPU 1 ...

Page 29: ...4 4 Description Guide 4 4 Memory Modules ...

Page 30: ...0 0 1 4 0 J8C4 CHE 0 M0 CPU0 CH4 DIMM0 Socket0 ChE Dimm0 F1 0 1 5 1 J9C7 CHF 1 M0 CPU0 CH5 DIMM1 Socket0 ChF Dimm1 sck0ch5 F0 0 1 5 0 J9C8 CHF 0 M0 CPU0 CH5 DIMM0 Socket0 ChF Dimm0 J0 1 0 2 0 J1C1 CHJ 0 M0 CPU1 CH2 DIMM0 Socket1 ChC Dimm0 sck1ch2 J1 1 0 2 1 J1C2 CHJ 1 M0 CPU1 CH2 DIMM1 Socket1 ChC Dimm1 H0 1 0 1 0 J1C3 CHH 0 M0 CPU1 CH1 DIMM0 Socket1 ChB Dimm0 sck1ch1 H1 1 0 1 1 J2C1 CHH 1 M0 CPU1...

Page 31: ...t Type 0 PCIe x8 blade PCIex16 blade 1 PCIe x8 blade 2 PCIe x8 blade PCIex16 blade 3 PCIe x8 blade 4 PCIe x8 blade dedicated to RAID SAS controller 5 Internal PCIe x16 connector dedicated to GPU card SAS card or NVME adapter 6 Internal PCIe x16 connector dedicated to GPU card ...

Page 32: ...e_70 3 3 Port 2C PCI PciePortDisable_68 4 3 Port 1A PCI PciePortDisable_64 5 3 Port 3A PCI PciePortDisable_72 6 2 Port 3A PCI PciePortDisable_51 2 0 4 Port 1C PCI PciePortDisable_85 1 4 Port 1A PCI PciePortDisable_87 2 5 Port 2A PCI PciePortDisable_112 3 5 Port 2C PCI PciePortDisable_110 4 5 Port 1A PCI PciePortDisable_106 5 5 Port 3A PCI PciePortDisable_114 6 4 Port 3A PCI PciePortDisable_93 3 0 ...

Page 33: ...4 8 Description Guide 4 6 Front Disk Blades FDB 4 6 1 FDB Numbering Front view Mark Description A FDB 0 B FDB 1 C FDB 2 D FDB 3 ...

Page 34: ...ute Unit Components 4 9 4 6 2 FDB Description Mark Description Quantity E SAS or SATA for the operating system disks 2 F Fan boxes 2 4 6 3 FDB Disks FDB disks identification Mark Description G Top disk H Bottom disk ...

Page 35: ... Mapping Physical mapping is identical for LSI SAS 9300 8i and LSI MegaRaid SAS 9361 8i cards Mark Disk Type Mapping I SAS SATA Drive Port 0 3 01 00 J SAS SATA Drive Port 0 3 01 02 K SAS SATA Drive Port 0 3 01 01 L SAS SATA Drive Port 0 3 01 03 M SAS SATA Drive Port 4 7 01 05 N SAS SATA Drive Port 4 7 01 04 O SAS SATA Drive Port 4 7 01 07 P SAS SATA Drive Port 4 7 01 06 ...

Page 36: ...ntroller Physical Mapping The table below describes the physical mapping for internal SATA RAID without additional adapter Mark Disk Type Mapping I None None J None None K None None L None None M SATA SATA Port 2 N None None O SATA SATA Port 3 P None None ...

Page 37: ...4 12 Description Guide 4 6 4 FDB Fan Boxes Top view Mark Description Q Fan box0 R Fan box1 ...

Page 38: ...ional Unit Components 5 1 Chapter 5 Optional Unit Components 5 1 Options According to the module configuration the optional unit may be equipped with Two GPUs Twelve 2 5 SAS disks Four 3 5 SAS disks Four NVME disks ...

Page 39: ...e 5 2 GPU Unit Single or double GPU configurations are possible 5 2 1 Components Top view Mark Description Quantity A GPU cards 2 B Top fan boxes 4 Note For a single GPU configuration there is only one GPU card on the left ...

Page 40: ...Chapter 5 Optional Unit Components 5 3 5 2 2 GPU Cards Numbering Top view Mark Description C GPU 0 D GPU 1 Note For a single GPU configuration there is only one GPU card GPU 0 ...

Page 41: ...Description Guide 5 2 3 GPU Fan Box Numbering Top view Mark Description E GPU 0 Fan box 0 F Fan box 1 G GPU 1 Fan box 0 H Fan box 1 Note For a single GPU configuration there are only two fan boxes for GPU 0 ...

Page 42: ... view Note Some of the components are located on the storage drawer Mark Description Quantity Location A 2 5 SAS disks 12 Storage drawer B PCIe RAID SAS controller card 1 Main box C SAS disk Backplane Boards SBB 2 Storage drawer D Top fan boxes 4 Storage drawer E SAS fan assembly 2 Main box ...

Page 43: ...5 6 Description Guide 5 3 2 SBB Positions Top view Mark Description F SBB2P5 0 E SBB2P5 1 ...

Page 44: ...ional Unit Components 5 7 5 3 3 Disk Numbering Top view Mark SBB2P5 Description G 0 Disk 0 Top H Bottom I Disk 1 Top J Bottom K Disk 2 Top L Bottom M 1 Disk 0 Top N Bottom O Disk 1 Top P Bottom Q Disk 2 Top R Bottom ...

Page 45: ... 12 12 O Disk 1 Top SAS Port 8 11 01 11 11 P Bottom SAS Port 8 11 01 08 8 Q Disk 2 Top SAS Port 8 11 01 10 10 R Bottom SAS Port 8 11 01 09 9 LSI 9305 16i Raid Controller Physical Mapping Mark SBB2P5 Description Mapping LSI Disk Port G 0 Disk 0 Top SAS Port 0 1 4 4 H Bottom SAS Port 0 1 7 7 I Disk 1 Top SAS Port 0 1 0 0 J Bottom SAS Port 0 1 3 3 K Disk 2 Top SAS Port 0 1 1 1 L Bottom SAS Port 0 1 2...

Page 46: ...Chapter 5 Optional Unit Components 5 9 5 3 4 Fan Box Numbering Top view Mark Description S Top Fan box 0 T Top Fan box 1 U Top Fan box 2 V Top Fan box 3 ...

Page 47: ... Note Some of the components are located on the storage drawer Mark Description Quantity Location A 3 5 SAS disks 4 Storage drawer B SAS disk Backplane Boards SBB 2 Storage drawer C PCIe RAID SAS controller card 1 Main box D Fan boxes 4 Storage drawer E SAS fan assembly 2 Main box ...

Page 48: ...Chapter 5 Optional Unit Components 5 11 5 4 2 SBB Positions Top view Mark Description I SBB3P5 Front J SBB3P5 Rear ...

Page 49: ...5 12 Description Guide 5 4 3 Disk Numbering Top view Disk Numbering and Physical Mapping Mark SBB3P5 Description Mapping E Front Disk 0 Port 7 F Disk 1 Port 4 G Rear Disk 0 Port 3 H Disk 1 Port 0 ...

Page 50: ...Chapter 5 Optional Unit Components 5 13 5 4 4 Fan Box Numbering Top view Mark Description K Fan box 0 L Fan box 1 M Fan box 2 N Fan box 3 ...

Page 51: ... Note Some of the components are located on the storage drawer Mark Description Quantity Location A 2 5 NVMe disks 4 Storage drawer B PCIe SAS controller card 1 Main Box C NVMe disk Backplane Boards NBB 2 Storage drawer D Fan boxes 4 Storage drawer E SAS fan assembly 2 Main Box ...

Page 52: ...Chapter 5 Optional Unit Components 5 15 5 5 2 NBB Positions Top view Mark Description E NBB Rear F NBB Front ...

Page 53: ...5 16 Description Guide 5 5 3 Disk Numbering Top view Mark Description G Rear Disk 0 I Disk 2 J Front Disk 0 L Disk 2 ...

Page 54: ...Chapter 5 Optional Unit Components 5 17 5 5 4 Fan Box Numbering Top view Mark Description M Fan Box 0 N Fan Box 1 O Fan Box 2 P Fan Box 3 ...

Page 55: ...6 UBox Components This chapter applies only to the Hitachi Advanced Server DS7160 6 1 Components Front view Exploded view Mark Description Quantity A LMB module 1 B CLKB module 2 C SCI module 2 D UNB fan module 12 or 24 E UNB module 2 or 4 ...

Page 56: ...6 2 Description Guide Rear view Mark Description Quantity F UBox PSU Up to 4 ...

Page 57: ...Chapter 6 UBox Components 6 3 6 2 Numbering 6 2 1 UNB Module Numbering Front view Mark Description A UNB module 0 B UNB module 1 C UNB module 2 D UNB module 3 ...

Page 58: ...6 4 Description Guide 6 2 2 UNB Memory Module Numbering Top view Mark Description M UNC 0 CH 1 N UNC 0 CH 0 O UNC 1 CH 1 P UNC 1 CH 0 Q UNC 2 CH 1 R UNC 2 CH 0 S UNC 3 CH 1 T UNC 3 CH 0 ...

Page 59: ...Chapter 6 UBox Components 6 5 6 2 3 SCI Module Numbering Front view Mark Description E SCI module 0 F SCI module 1 ...

Page 60: ...e Numbering Front view Mark Description G CLKB module 0 H CLKB module 1 6 2 5 UNB Fan Module Numbering UNB fan modules are numbered from 0 to 5 for each UNB module The UNB fan modules for UNB module 1 are shown in the image below Front view ...

Page 61: ...ox model System configuration Voltage range Population rule Redundancy Two UNB modules 100 110V PSU 0 PSU 1 PSU 2 or 3 2 1 redundancy 200 240V PSU 0 PSU 1 1 1 redundancy Four UNB modules 100 110V PSU 0 PSU 1 PSU 2 PSU 3 3 1 redundancy 200 240V PSU 0 PSU 1 PSU 2 or 3 2 1 redundancy Important Regardless of the system configuration voltage range and PSU redundancy the UBox cannot function if both PSU...

Page 62: ...y four seconds Front view Mark Color Description Component A Green solid OS booting Power On Management Board Right Side MRB Green blinking Standby LED pattern time in seconds Bios booting LED pattern time in seconds Booted to EFI LED pattern time in seconds B Blue Module Identification BMC booting Management Board Right Side MRB D Red Fan box failure one LED for 2 fan boxes FDB 0 fan boxes E FDB ...

Page 63: ... Description Color K Green Amber Disk activity Disk failure FDB 1 Bottom Disk L FDB 2 Top Disk M FDB 2 Bottom Disk N FDB 3 Top Disk O FDB 3 Bottom Disk P Red GPU unit fan box failure one LED for two fan boxes GPU fan boxes Q GPU fan boxes ...

Page 64: ... Component A Green solid OS booting Power On Management Board Right Side MRB Green blinking Standby LED pattern time in seconds Bios booting LED pattern time in seconds Booted to EFI LED pattern time in seconds B Blue Module Identification BMC booting Management Board Right Side MRB D Red Fan box failure one LED for two fan boxes FDB 0 fan boxes E FDB 1 fan boxes F FDB 2 fan boxes G FDB 3 fan boxe...

Page 65: ...7 4 Description Guide Mark Component Description Color P Red Top fan box failure Fan box 0 Q Fan box 1 R Fan box 2 S Fan box 3 T Red SAS fan box failure SAS fan module 1 U SAS fan module 2 ...

Page 66: ...er 7 LEDs Buttons and Ports 7 5 7 1 3 UBox LEDs This section applies to the Hitachi Advanced Server DS7160 only 7 1 3 1 CLKB module LEDs Front view Mark Color Description A Amber Power B Blue Identification ...

Page 67: ...7 6 Description Guide 7 1 3 2 UNB fan module LEDs Front view Mark Color Description C Red Fault 7 1 3 3 UNB module LEDs Front view Mark Color Description D Amber Power E Blue Identification ...

Page 68: ...k activity J Green LMB module Peer ethernet link activity K Green Module 0 ethernet link activity L Green Module 1 ethernet link activity M Green Module 2 ethernet link activity N Green Module 3 ethernet link activity O Green Module 4 ethernet link activity P Green Module 5 ethernet link activity Q Green Module 6 ethernet link activity R Green Module 7 ethernet link activity ...

Page 69: ...onent A Power on Management Board Right Side MRB B Module identification Management Board Right Side MRB C BMC reset Management Board Right Side MRB 7 1 4 2 UBox Buttons Front view Mark Button Component A Firmware recovery button LMB module B Power button LMB module C Reset button LMB module ...

Page 70: ...ed E Solid green Power Supply Unit PSU powered on Power Supply Unit PSU Blinking green Power Supply Unit PSU on stand by Solid amber Power Supply Unit PSU failure F Blinking blue Identification Phy Ethernet Board PEB G Red System powered on in firmware recovery mode Blinking red PEB flash firmware is updated Off System powered on in normal mode H Yellow Link 1 Gb s Ethernet up Green Link 10 Gb s E...

Page 71: ...ng green Power Supply Unit PSU on stand by Amber Power Supply Unit PSU failure F Blinking blue Identification Phy Ethernet Board SFP PEBS G Red System powered on in firmware recovery mode Off System powered on in normal mode H Orange Link 1 Gb s Ethernet up I Blinking yellow Ethernet link activity Off No Ethernet link activity J Yellow Link 1 Gb s Ethernet up Green Link 10 Gb s Ethernet up K Blink...

Page 72: ...een Blinking green Solid amber Power Supply Unit PSU powered on Power Supply Unit PSU on stand by Power Supply Unit PSU failure Power Supply Unit PSU F Blue Identification Phy Ethernet Board PEB G Red System powered on in firmware recovery mode Blinking red PEB flash firmware is updated Off System powered on in normal mode Phy Ethernet Board PEB H Yellow Link 1 Gb s Ethernet up Green Link 10 Gb s ...

Page 73: ...7 12 Description Guide Mark Component Description Color L Green Activity sWitch Ethernet One Gigabit WEO M Amber Green Powering on Power on Case of a PEBS ...

Page 74: ...ply Unit PSU failure Power Supply Unit PSU F Blinking blue Identification Phy Ethernet Board SFP PEBS G Red System powered on in firmware recovery mode Off System powered on in normal mode H Orange Link 1 Gb s Ethernet up I Blinking yellow Ethernet link activity Off No Ethernet link activity J Yellow Link 1 Gb s Ethernet up Green Link 10 Gb s Ethernet up K Blinking yellow Ethernet link activity Of...

Page 75: ...n Guide 7 2 3 Buttons Rear view Case of a PEB Case of a PEBS Mark Button Component A Attention button PCI e x8 blade or PCI e x16 blade B Firmware recovery button Phy Ethernet Board PEB or Phy Ethernet Board SFP PEBS ...

Page 76: ...Chapter 7 LEDs Buttons and Ports 7 15 7 3 Internal LEDs 7 3 1 2 5 SAS Disks Storage Unit Front view Mark Color Description Component A Green Amber Disk activity Disk failure SAS 2 5 backplane ...

Page 77: ...7 16 Description Guide 7 3 2 3 5 SAS Disks Storage Unit Front view Mark Color Description Component A Green Amber Disk activity Disk failure SAS 3 5 backplane ...

Page 78: ...Chapter 7 LEDs Buttons and Ports 7 17 7 3 3 NVMe Disks Storage Unit Front view Mark Color Description Component A Green Amber Disk activity Disk failure NVMe backplane ...

Page 79: ...Management Board Left Side MLB C VGA port Management Board Right Side MRB Rear view Case of a PEB Mark Type Component 0 1 2 3 RJ45 10 Gb s 1 Gb s Ethernet Phy Ethernet Board PEB Case of a PEBS Mark Type Component 0 1 RJ45 1 Gb s Ethernet Phy Ethernet Board SFP PEBS 2 3 SFP 10 Gb s 1 Gb s Ethernet Phy Ethernet Board SFP PEBS ...

Page 80: ...Relative humidity non condensing 20 to 60 Gradient 5 hour Pressure Elevation Sea level 2500m Non Operating Limits Ambient air temperature 5 C and 50 C Relative humidity non condensing 5 and 95 Gradient 30 h Moisture content 0 024 kg water kg dry air Shipping Limits Operating air temperature 10 C to 70 C Gradient 25 C hour Relative humidity non condensing 5 to 95 Gradient 30 hour ...

Page 81: ...th 850 mm Weight Up to 43 Kg Hitachi Advanced Server DS7040 Height 4U 175 mm Width 446 mm Depth 850 mm Weight Up to 81 Kg Hitachi Advanced Server DS7080 Height 8U 352 60 mm Width 446 mm Depth 850 mm Weight Up to 160 Kg Hitachi Advanced Server DS7160 Height 21U 930 mm Width 446 mm Depth 850 mm Weight Up to 415 Kg ...

Page 82: ...3 C14 10 16A PDU cable type C13 C14 10 16A Electrical Specifications Each module is equipped with 2 PSU with 2 C13 C14 cable connections Rated Current 7 7 A Power consumption Typical 1200W Thermal dissipation Maximum 1400W Rated Voltage Range 100 110 V 200 240 V Rated Frequency Range 50 60 hz Environmental Specifications Noise 47db ...

Page 83: ... 16A PDU cable type C13 C14 10 16A Electrical Specifications A UBox is equipped with up to4 PSU with 4 C13 C14 cable connections Rated Current 7 7 A Power consumption Typical 1200W Thermal dissipation Maximum 1400W Rated Voltage Range 100 110 V 200 240 V Rated Frequency Range 50 60 hz Environmental Specifications Noise 47db ...

Page 84: ...ler UPI protocol between CPU sockets and UNC Maximum Ultra Path Interconnect at 11 2 GT s SCI protocol between UNCs Maximum Scalable Coherent Interface at 10 4 GT s Memory Minimum Maximum Hitachi Advanced Server DS7020 64 GB up to 3 TB Hitachi Advanced Server DS7040 128 GB up to 6 TB Hitachi Advanced Server DS7080 256 GB up to 12 TB Hitachi Advanced Server DS7160 512 GB up to 24 TB Type DDR4 RDIMM...

Page 85: ... Line Interface CPB CPU Purley Board Motherboard CPLD Complex Programmable Logic Device CPU Central Processing Unit CRU Customer Replaceable Unit CSR Certificate Signing Request D DDR4 Double Date Rate fourth generation DES Data Encryption Standard DFMB Front Disk Blade Board DFMR Front Disk Blade Riser DHCP Dynamic Host Configuration Protocol DIMM Dual In line Memory Module DNS Domain Name Server...

Page 86: ...le F FDB Front Disk Blade FPGA Field Programmable Gate Array FQDN Fully Qualified Domain Name FRU Field Replaceable Unit G GPU Graphical Processing Unit H HDD Hard Disk Drive I I2C Intra Integrated Circuit iCare insight Care IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface J JRE Java Runtime Environment ...

Page 87: ...B Local Management Board LMC Local Management Controller M MAC Media Access Control MLB Management Board Left Side MRB Management Board Right Side MESCA Multiple Environments on a Scalable Csi based Architecture MIB Management Interface Base MSM Management Switch Module N NBB NVMe disk Backplane Board NEMA National Electrical Manufacturers Association NFC Near Field Communication NTP Network Time ...

Page 88: ...HY Ethernet Board PEBS PHY Ethernet Board SFP PEF Platform Event Filtering PET Platform Event Trap PHP PHP Hypertext Preprocessor PIROM Processor Information ROM PSU Power Supply Unit R RADIUS Remote Authentication Dial In User Service RAID Random Array of Independent Disks RAS Reliability Availability Serviceability RDIMM Registered Dual In line Memory Module RFB Remote Frame Buffer RMC Rack Mana...

Page 89: ...tate Drive SDDC Single Device Data Correction SDR Sensor Data Repository SEL System Event Log SHC Server Hardware Console SMTP Simple Mail Transfer Protocol SNMP Simple Network Management Protocol SOL Serial Over LAN SSH Secured Shell SSL Secure Socket Layer T TELNET TELecommunication NETwork U UNB UNC Board UNC UPI Node Controller UPI Ultra Path Interconnect ...

Page 90: ...cal Infrastructure UPS Uninterruptible Power Supply URS USB Raid SD Card V VGA Video Graphics Array VLAN Virtual Local Area Network VM Virtual Machine W WEO sWitch Ethernet One Gigabit X XNC External Node Controller Y No entries Z No entries ...

Page 91: ...USA www HitachiVantara com community HitachiVantara com Regional Contact Information Americas 1 866 374 5822 or info hitachivantara com Europe Middle East and Africa 44 0 1753 618000 or info emea hitachivantara com Asia Pacific 852 3189 7900 or info marketing apac hitachivantara com ...

Reviews: