background image

Installation

 Guide

)JUBDIJ"EWBODFE4FSWFS%4

 Series

MK-97HAS7013-02
August 2020

Summary of Contents for DS7000 Series

Page 1: ...Installation Guide JUBDIJ EWBODFE 4FSWFS 4 Series MK 97HAS7013 02 August 2020 ...

Page 2: ...S Outlook PowerPoint SharePoint Silverlight SmartScreen SQL Server Visual Basic Visual C Visual Studio Windows the Windows logo Windows Azure Windows PowerShell Windows Server the Windows start button and Windows Vista are registered trademarks or trademarks of Microsoft Corporation Microsoft product screen shots are reprinted with permission from Microsoft Corporation All other trademarks service...

Page 3: ... 2 Installing a Hitachi DS7040 Server 2 7 2 3 Installing a Hitachi DS7080 Server 2 14 2 4 Installing a Hitachi DS7160 Server 2 21 2 4 1 Installing the rails for the Hitachi DS7080 Server Assemblies 2 21 2 4 2 Installing the Rails for the UBox 2 27 2 4 3 Installing all the Chassis 2 31 2 4 4 Installing the 8 Module Connecting Box 2 36 2 4 5 Installing the UBox Components 2 43 Appendix A Installing ...

Page 4: ......

Page 5: ...mware updates software fixes and service offers http support HitachiVantara com Intended Readers This guide is intended for use by qualified personnel in charge of installing the server cabinet D049 DANGER D049 The product must not be used in life support system or other applications where failure could threaten injury or life and any such use voids the limited warranty associated to the product ...

Page 6: ......

Page 7: ...er packaging for damage W020 WARNING W020 The server drawer must not be unpacked before it has reached the room temperature 24 hours in the computer room According to the server configuration the following items are included Compute Box fully populated Empty UBox UBox components 8 module connecting box 16 module connecting box Rack mounting kits Screws and washers ...

Page 8: ...odel Name Commercial Name M3S2G2 Hitachi DS7020 server M3S2G4 Hitachi DS7040 server M3S2G8 Hitachi DS7080 server M3XU16 UBox 1 2 2 Identifying Server Modules Server modules are identified by an identification label The label gives the MAC address of the BMC embedded management controller Rear view The label is located inside a little drawer Master Label Example ...

Page 9: ...Chapter 1 Checking the Delivery Contents 1 3 Slave Label Example Front view A label is also available at the front behind the bezel ...

Page 10: ...ule Labels Server Identification Label The label is located on the side of the server Mark Description A Recycling symbol indicates the mandatory obligation to reuse and recycle electronic and electrical equipment properly B Tropicalization symbol indicates that the device must be operated within the adequate limits of temperature and humidity C Altitude symbol indicates that the device must not b...

Page 11: ... interference and 2 this device must accept any interference received including interference that may cause undesired operation Server Module Identification Label Rear view The label is located inside a little drawer C044 CAUTION C044 This unit has more than one power supply cord Disconnect all power supply cords from the unit before servicing Electrical Hazard Symbol Indicates risk of electric sh...

Page 12: ...ling symbol indicates the mandatory obligation to reuse and recycle electronic and electrical equipment properly B Tropicalization symbol indicates that the device must be operated within the adequate limits of temperature and humidity C Altitude symbol indicates that the device must not be operated at an altitude higher than 2000 meters ...

Page 13: ... received including interference that may cause undesired operation UBox Onboard Battery Label C003 CAUTION C003 The onboard battery should be replaced regularly It must be replaced with the same or an equivalent type recommended by the manufacturer There is a danger of explosion if another type is used Dispose of used batteries according to the manufacturer s instructions UBox Power Supply Unit P...

Page 14: ...044 This unit has more than one power supply cord Disconnect all power supply cords from the unit before servicing Proceed as follows 1 Power OFF the server 2 Switch OFF the site power breakers 3 Remove all power supply cords from the unit ...

Page 15: ...k it and install it in the cabinet Important The server is delivered fully populated It is mandatory to use a lifting device to install it However it is possible to reduce the server weight by removing the components from the compute box See Appendix Installing a Lightened Server on page A 1 Required screws nuts and washers See Appendix Nuts Screws and Washers on page B 1 Required tools T25 Torx s...

Page 16: ...2 2 Installation Guide Procedure 1 Prepare the rails 1 Loosen the four screws of each rail ...

Page 17: ...Chapter 2 Installing the Server in the Rack Cabinet 2 3 2 Adjust the length of each rail 3 Tighten the four screws of each rail ...

Page 18: ...2 4 Installation Guide 2 From the front install the left rail ...

Page 19: ...Chapter 2 Installing the Server in the Rack Cabinet 2 5 3 From the front install the right rail ...

Page 20: ...on Guide 4 From the front install the Hitachi DS7020 server compute box Insert the server using the guiding pins 5 Secure the server in place 1 Push the server until it stops 2 Tighten both captive screws Front view ...

Page 21: ...delivered fully populated It is mandatory to use a lifting device to install it However it is possible to reduce the server weight by removing the components from the compute box See Appendix Installing a Lightened Server on page A 1 Required screws nuts and washers See Appendix Nuts Screws and Washers on page B 1 Required tools T25 Torx screwdriver Flat screwdriver Lifting device ...

Page 22: ...2 8 Installation Guide Procedure 1 Prepare the rails 1 Loosen the four screws of each rail ...

Page 23: ...Chapter 2 Installing the Server in the Rack Cabinet 2 9 2 Adjust the length of each rail 3 Tighten the four screws of each rail ...

Page 24: ...2 10 Installation Guide 2 From the front install the left rail ...

Page 25: ...Chapter 2 Installing the Server in the Rack Cabinet 2 11 3 From the front install the right rail ...

Page 26: ...2 12 Installation Guide 4 From the front install the Hitachi DS7040 server compute box ...

Page 27: ...Chapter 2 Installing the Server in the Rack Cabinet 2 13 5 Secure the Hitachi DS7040 server compute box in place 1 Push the server until it stops 2 Tighten the four captive screws Front view ...

Page 28: ... lifting device to install it However it is possible to reduce the server weight by removing the components from the compute box See Appendix Installing a Lightened Server on page A 1 Required screws nuts and washers See Appendix Nuts Screws and Washers on page B 1 Required tools T25 Torx screwdriver Flat screwdriver Lifting device Procedure 1 Prepare the rails 1 Loosen the four screws of each rai...

Page 29: ...Chapter 2 Installing the Server in the Rack Cabinet 2 15 2 Adjust the length of each rail 3 Tighten the four screws of each rail ...

Page 30: ...2 16 Installation Guide 2 From the front install the left rail ...

Page 31: ...Chapter 2 Installing the Server in the Rack Cabinet 2 17 3 From the front install the right rail ...

Page 32: ...2 18 Installation Guide 4 Install the Hitachi DS7080 server compute box 1 Insert the Hitachi DS7080 server compute box into the rack cabinet ...

Page 33: ... the Server in the Rack Cabinet 2 19 2 Push the server until the front face is 5 cm from the rack cabinet edge 3 Insert two cage nuts in the rack cabinet frames for the upper server screws 4 Push the server until it stops ...

Page 34: ...2 20 Installation Guide 5 Secure the Hitachi DS7080 server compute box into place Tighten the four captive screws ...

Page 35: ...d Required screws nuts and washers See Appendix Nuts Screws and Washers on page B 1 Required tools T10 Torx screwdriver T20 Torx screwdriver T25 Torx screwdriver PH1 Cross headed screwdriver Flat screwdriver Lifting device 2 4 1 Installing the rails for the Hitachi DS7080 Server Assemblies Procedure 1 Prepare the rails 1 Loosen the four screws of each rail ...

Page 36: ...2 22 Installation Guide 2 Adjust the length of each rail 3 Tighten the four screws of each rail ...

Page 37: ...Chapter 2 Installing the Server in the Rack Cabinet 2 23 2 From the front install the left rail at the bottom of the rack rack slot 1 ...

Page 38: ...2 24 Installation Guide 3 From the front install the right rail at the bottom of the rack rack slot 1 ...

Page 39: ...Chapter 2 Installing the Server in the Rack Cabinet 2 25 4 Place the other set of rails at the rack slot 14 at the left Perform the operations to secure in place the second set of rails ...

Page 40: ...2 26 Installation Guide 5 Place the other set of rails at the rack slot 14 at the right Perform the operations to secure in place the second set of rails ...

Page 41: ...Chapter 2 Installing the Server in the Rack Cabinet 2 27 2 4 2 Installing the Rails for the UBox Procedure 1 Prepare the rails 1 Loosen the four screws of each rail 2 Adjust the length of each rail ...

Page 42: ...2 28 Installation Guide 3 Tighten the four screws of each rail ...

Page 43: ...Chapter 2 Installing the Server in the Rack Cabinet 2 29 2 From the front install the left rail at the rack slot 9 ...

Page 44: ...2 30 Installation Guide 3 From the front install the right rail at the rack slot 9 ...

Page 45: ... 2 Installing the Server in the Rack Cabinet 2 31 2 4 3 Installing all the Chassis Procedure 1 Install the Hitachi DS7080 server compute box 1 Insert the Hitachi DS7080 server compute box into the rack cabinet ...

Page 46: ...2 Installation Guide 2 Push the server until the front face is 5 cm from the rack cabinet edge 3 Insert two cage nuts in the rack cabinet frames for the upper server screws 4 Push the server until it stops ...

Page 47: ...Chapter 2 Installing the Server in the Rack Cabinet 2 33 2 Secure the Hitachi DS7080 server compute box into place Tighten the four captive screws ...

Page 48: ...2 34 Installation Guide 3 Install the empty UBox at the rack slot 9 1 Insert the UBox into the rack cabinet 2 Push the UBox until it stops 4 Secure the UBox in place Tighten the four captive screws ...

Page 49: ...apter 2 Installing the Server in the Rack Cabinet 2 35 5 Install the Hitachi DS7080 server assembly at the rack slot 14 Perform the operations to secure in place the second Hitachi DS7080 server assembly ...

Page 50: ...2 36 Installation Guide 2 4 4 Installing the 8 Module Connecting Box Procedure 1 Take hold of the new component 1 Loosen the fixing pins A and the captive screws B 2 Remove the cover using the handles C ...

Page 51: ...Chapter 2 Installing the Server in the Rack Cabinet 2 37 2 Partially insert the 8 module connecting box into its location Watch out for the position of the 8 module connecting box Rear view ...

Page 52: ...2 38 Installation Guide 3 Remove the shipping brackets Four brackets are installed for shipment and must be removed 1 Loosen the captive screws ...

Page 53: ...Chapter 2 Installing the Server in the Rack Cabinet 2 39 2 Remove the brackets ...

Page 54: ...2 40 Installation Guide 4 Secure the 8 module connecting box in place 1 Push the 8 module connecting box completely in ...

Page 55: ...Chapter 2 Installing the Server in the Rack Cabinet 2 41 2 Tighten the captive screws A and fixing pins B ...

Page 56: ...2 42 Installation Guide 5 Install the cover 1 Install the cover using the handles C 2 Secure the cover in place by tightening the fixing pins A and the captive screws B ...

Page 57: ... label inside the PSU slot 2 Press the latch of the UBox PSU 3 Push the UBox PSU in using the handle 4 Release the latch to secure the UBox PSU in place 2 4 5 Installing the UBox Components Procedure 1 Take hold of the new component 2 Install all the UNB modules For each UNB module perform the following steps 1 Check the handles of the UNB module are in the open position ...

Page 58: ...2 44 Installation Guide 2 Insert the UNB module and push it completely 3 Close the handles 4 Tighten the captive screw on the handles ...

Page 59: ... 2 45 3 Install all the SCI modules For each SCI module perform the following steps 1 Check the handle of the SCI module is in the open position 2 Insert the SCI module and push it completely 3 Close the handle 4 Tighten the captive screw on the handle ...

Page 60: ...llation Guide 4 Install the LMB module 1 Check the handles of the LMB module are in the open position 2 Insert the LMB module and push it completely 3 Close the handles 4 Tighten the captive screw on the handles ...

Page 61: ...ll the CLKB modules For each CLKB module perform the following steps 1 Insert the CLKB module 2 Push it completely 6 Install all the UNB fan modules For each UNB fan module perform the following steps Insert the UNB fan module and push it completely using the handle ...

Page 62: ...2 48 Installation Guide 7 Install the UBox bezel 1 Put in place the bezel 2 Check the position of the pilot pin B with the hole C 3 Tighten the captive screws A ...

Page 63: ...ossible to reduce the server weight by removing the components from the compute box However it is mandatory to use a lifting device A 1 Removing all the Components from the Compute Box 1 Carefully remove the main boxes and all the PSUs and all the PCIe blades 2 Unlock the main box 1 Loosen both captive screws 2 Release both handles 3 Pull the handles down at the same time to release the main box ...

Page 64: ...A 2 Installation Guide 4 Pull the main box out of the compute box by the handles 3 Unlock the latch of the PCIe blade 4 Take hold of the handle and carefully remove the PCIe blade ...

Page 65: ...A 3 Appendix A Installing a Lightened Server 5 Pull the latch of the PSU up 6 Take hold of the handle and carefully remove the PSU ...

Page 66: ...he Compute Box in the Rack Cabinet Proceed in the same way as for the fully populated server It is mandatory to use a lifting device 1 From the front install the compute box 2 Secure the compute box in place by tightening the captive screws ...

Page 67: ...ed Server A 3 Installing the Components into the Compute Box 1 Carefully install the main boxes all the PCIe blades and the PSUs 2 From the front insert the main box into the compute box 3 Secure the main box in place 1 Lift both handles ...

Page 68: ...A 6 Installation Guide 2 Tighten both captive screws 4 Install the PSUs at the rear 1 Look at the labels on the PSU slot sides to check the PSU positions ...

Page 69: ...e left hand side with the latch B at the bottom Rear view 3 Take hold of the PSU by the handle A 4 Push the PSU using the handle A until the latch B locks 5 Position a PSU in the slot on the right hand side with the latch B at the top Rear view 6 Take hold the PSU by the handle A ...

Page 70: ... Installation Guide 7 Push the PSU using the handle A until the latch B locks 5 Locate all the PCIe blades slots for a module Rear view 6 Install all the PCIe blades For all PCIe blades 1 Unlock the latch ...

Page 71: ...A 9 Appendix A Installing a Lightened Server 2 Insert the PCIe blade into the compute box using the handle 3 Check that the latch is closed ...

Page 72: ......

Page 73: ...Appendix B Nuts Screws and Washers This appendix describes all nuts screws and washers included in the delivery Screws Mark Head Body Diameter Length S1 5 mm 16 mm Washers Mark Head Body Diameter W1 5 mm Nuts Mark Head Body Diameter N1 5 mm ...

Page 74: ...B 2 Installation Guide ...

Page 75: ......

Page 76: ... RUSRUDWH HDGTXDUWHUV VHVTUJOF SJWF 6DQWD ODUD 86 LWDFKL9DQWDUD FRP FRPPXQLW LWDFKL9DQWDUD FRP RQWDFW QIRUPDWLRQ 64 MPCBM JUBDIJ7BOUBSB DPN DPOUBDU Hitachi 9DQWDUD ...