88
LLDP Configuration Parameters:
Items
Description
Tx Interval
The switch periodically transmits LLDP frames to its neighbors for having the network
discovery information up-to-date. The interval between each LLDP frame is determined by
the Tx Interval value. Valid values are restricted to 5 - 32768 seconds.
Tx Hold
Each LLDP frame contains information about how long the information in the LLDP frame
shall be considered valid. The LLDP information valid period is set to Tx Hold multiplied by Tx
Interval seconds. Valid values are restricted to 2 - 10 times.
Tx Delay
If some configuration is changed (e.g. the IP address) a new LLDP frame is transmitted, but
the time between the LLDP frames will always be at least the value of Tx Delay seconds. Tx
Delay cannot be larger than 1/4 of the Tx Interval value. Valid values are restricted to 1 -
8192 seconds.
Tx Reinit
When a port is disabled, LLDP is disabled or the switch is rebooted, an LLDP shutdown
frame is transmitted to the neighboring units, signaling that the LLDP information isn't valid
anymore. Tx Reinit controls the amount of seconds between the shutdown frame and a new
LLDP initialization. Valid values are restricted to 1 - 10 seconds.
LLDP Port Configuration
The LLDP port settings relate to the currently selected entry as reflected by the page header.
Port
The switch port number of the logical LLDP port.
Mode
Select LLDP mode.
RX Only: the switch will not send out LLDP information, but LLDP information from neighbor
units is analyzed.
Tx Only: The switch will drop LLDP information received from neighbors, but will send out
LLDP information.
Disabled: The switch will not send out LLDP information, and will drop LLDP information
received from neighbors.
Enabled: The switch will send out LLDP information and will analyze LLDP information
received from neigh ours.