Utilization
The best estimate of the mean physical layer network utilization on this interface during this
sampling interval, in hundredths of a percent.
Buttons
Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs
every 3 seconds.
Refresh: Click to refresh the page immediately.
<<: Updates the table starting from the first entry in the History table, i.e., the entry with the
lowest History Index and Sample Index
>: Updates the table, starting with the entry after the last entry currently displayed
RMON Alarm
This page provides an overview of RMON Alarm entries. Each page shows up to 99 entries from the Alarm table, default
being 20, selected through the "entries per page" input field. When first visited, the web page will show the first 20
entries from the beginning of the Alarm table. The first displayed will be the one with the lowest ID found in the Alarm table.
The "Start from Control Index" allows the user to select the starting point in the Alarm table. Clicking the button will update
the displayed table starting from that or the next closest Alarm table match. The form will use the last entry of the
currently displayed entries as a basis for the next lookup. When the end is reached the text "No more entries" is shown in
the displayed table.
To display the ROMON Alarm Overview in the web interface:
Click Monitor / Security / Switch / RMON / Alarm
Enter a Start from Control Index and the number of entries to be displayed per page.
Check the Auto-Refresh check box to have the page automatically refresh every 3 seconds.
RMON Histroy Overview Parameters:
Items
Description
ID
Indicates the index of Alarm control entry.
Interval
Indicates the interval in seconds for sampling and comparing the rising and falling threshold.
Variable
Indicates the particular variable to be sampled.
Sample Type
The method of sampling the selected variable and calculating the value to be compared against
the thresholds.
Value
The value of the statistic during the last sampling period.
Startup Alarm
The alarm that may be sent when this entry is first set to valid.
Rising Threshold
Rising Threshold value.
Falling Threshold
Falling threshold value.
Buttons
Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs
every 3 seconds.
Refresh: Click to refresh the page immediately.
<<: Updates the table starting from the first entry in the History table, i.e., the entry with the
lowest History Index and Sample Index
>: Updates the table, starting with the entry after the last entry currently displayed.