POWER
INSTALLING THE EXTENDED BATTERY
BACKUP KIT
HySecurity offers extended DC power back
up option with two 50Ah batteries. Contact
HySecurity parts department to order extended
battery backup kit (P/N MX001810).
To install the extended battery backup kit:
1.
Turn off the DC and AC power switches.
2.
Unlock side latches to remove the SwingSmart
front cover. Remove the two Phillips-head
screws and the two wing nuts that secure the
rear cover. Set the covers aside.
3.
Cut the two black zip ties which secure the 8Ah
batteries to the tray.
4.
To access the 8Ah batteries and disconnect
its wires, remove the two screws closest to the
motor and loosen the other two screws that
secure the support tray as shown in Figure 24
.
Figure 24. 50 Amp Battery Installation
Accessory Tray
AC power switch
in the off position
DC power switch
in the off position
Loosen tray
screws (2x)
Remove tray screws (2x) and
rotate the tray down to remove
the batteries.
5.
Carefully rotate the support tray to access the
battery wires. Lift the 8Ah batteries from the
support tray. Disconnect the black and blue
wires and set the 8Ah batteries aside.
6.
Return the support tray to it’s original position
and secure it properly.
7.
Place the 50Ah battery tray between the
chassis posts and secure it using the four
fasteners provided in the kit. See Figure 25
.
Figure 25. 50 Amp Battery Harness Installation
8.
Situate the two 50Ah batteries on the tray.
Attach the blue wire from the red terminal on
one 50Ah battery to the black terminal on other
50Ah battery.
9.
Run the 8Ah wire harness through hole in the
8Ah battery support tray.
10.
Using the wires attached in the 50Ah battery
kit, attach the red wire to the red positive
terminal on the 50Ah battery. Connect its
opposite end to the red lead exiting the
support tray. Connect the black wire to the
black negative terminal on the 50Ah battery.
Connect its opposite end to the black lead
exiting the support tray.
11.
Access the Installer Menu on the Smart DC
Controller.
Accessory Tray
50
| www.hysecurity.com
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
MX3640-01 REV. D ©2018
Содержание SwingSmart DC 20
Страница 2: ...2 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 24: ...SAFETY INFORMATION 24 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 138: ...NOTES 138 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 139: ...NOTES 139 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...