Figure 73. Vehicle Detectors and Loop Layout for Openings Greater than 28 feet*
B
ENTER
EXIT
OBSTRUCTION
LOOP
A
ACCESS CONTROL DEVICE
(Card reader, etc.)
Vehicle Detectors and Loop Layout for Openings greater than 28 feet*
PUBLIC SIDE
This layout illustrates a
bi-direconal traffic system with
controlled access entry (card
reader, radio control, etc.) and a
free exit gate. The gate is closed
by a TIMER TO CLOSE. The ming
to close starts when all loops are
clear. The mer is adjustable
from 1 to 99 seconds.
For a single-direconal system,
the FREE EXIT loop is replaced by
an OBSTRUCTION loop.
the FREE EXIT loop is replaced by
an OBSTRUCTION loop.
SECURE SIDE
C
D
E
F
CENTER
LOOP
FREE EXIT
or
OBSTRUCTION
LOOP
* NOTE: A minimum of three (3) detectors are required for this type of gate.
DIMENSIONS
A
= 6 to 8 feet (2 meters to 243cm)
B
= 6 to 12 (2m to 366cm)
C
= Maintain 4 (122cm)
D
= Maintain 5 (152cm) between loop
and edge of roadway. No vehicle can pass
through such a small area and escape detecon.
E
= Maximum 4 (122cm). Vehicle must be
able to pass from one loop to the next
without loss of detecon.
F
= The distance from gate to FREE EXIT
LOOP is equal to the gate panel length
plus 4 (122cm).
G
= 4 to 6 (122cm to 2m).
OBSTRUCTION
LOOP
CENTER
LOOP
FREE EXIT
or
OBSTRUCTION
LOOP
G
REFERENCE
117
| www.hysecurity.com
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
MX3640-01 REV. D ©2018
Содержание SwingSmart DC 20
Страница 2: ...2 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 24: ...SAFETY INFORMATION 24 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 138: ...NOTES 138 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 139: ...NOTES 139 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...