DC BATTERY REPLACEMENT
HySecurity provides a one year warranty from the
date of shipment for all batteries supplied with
the SwingSmart DC operator.
Display indicators of a low battery include:
z
LOW BATTERY or DEAD BATTERY appears on
the Smart DC Controller display which may or
may not be indicative of normal discharge.
z
ALERT 18 CHANGE BATTERY appears on the
Smart DC Controller display. The operator
emits an audible chirp every minute to indicate
a problem exists.
z
AP (#) AC LOSS appears on the Smart DC
Controller display. Gate operation is affected
by AC power loss depending on customer
preferences and the configuration set by the
installer in the AP (#) AC LOSS User Menu. For
more information, refer to Setting AC Power
Loss Gate Function on page 51.
Symptoms of a low battery may include:
z
Gate remains locked in the open position
z
Gate remains locked in the closed position
z
Gate opens five seconds after AC power loss
and locks open
CAUTION
Before replacing the batteries, turn off all
power switches. Use only AGM batteries
as replacements (8Ah - MX002008, 50Ah -
MX002013). The batteries supplied in the
SwingSmart operator are state-of-the-art AGM
batteries. Do NOT use flooded cell batteries as
damage may occur to the unit. Wear protective
clothing while working with batteries.
GENERAL MAINTENANCE
The two 8Ah batteries are accessible within the
operator on a tray behind the control box.
To replace the batteries, see Figure 63, and take
the following steps:
1.
Remove the covers. If unfamiliar with removing
the covers, refer to the Quick Start Steps.
2.
Turn off the DC and AC power switches.
3.
Cut the black wire ties holding the batteries
to the shelf.
4.
Disconnect the red, blue jumper, and black
wires before removing the batteries.
5.
Loosen the two rear screws and remove the
front two screws that secure the support tray.
6.
Carefully rotate the support tray to access the
battery wires and disconnect the black and
blue wires.
7.
Remove the first battery from the support tray.
8.
Slide the second battery to the right, disconnect
the red and black wires and remove it from the
tray.
Figure 63. Drive Belt Tension and Alignment
Loosen rear
tray screws (2x)
Remove front
tray screws (2x)
and rotate the
tray down to
remove both
batteries.
106
| www.hysecurity.com
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
MX3640-01 REV. D ©2018
Содержание SwingSmart DC 20
Страница 2: ...2 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 24: ...SAFETY INFORMATION 24 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 138: ...NOTES 138 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 139: ...NOTES 139 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...