BI-PARTING/DUAL GATE SYSTEM
PRIMARY AND SECONDARY WIRING
CONNECTIONS
1.
As shown in Figure 56, connect a two-pair,
twisted, shielded communications cable to
the DUAL GATE inputs in each unit. The inputs
are located near the base of the Smart DC
Controller. Be sure to connect the wires in pairs
to the same terminal ports (A-A, B-B, and COM
to COM) on both units. See Table 17
2.
Attach a ring terminal to the shield wire
and connect it to the Smart DC Controller’s
convenient ground screw. Refer to Figure 56
.
NOTICE
Connect the ground shield wire to only one
operator, not both.
Table 17. Primary-Secondary Wiring
Primary
Secondary
A
A
COM
COM
B
B
* Only ground to one unit. Do NOT attach the
shield wire to both units.
Shield wire to Ground*
Figure 56. Primary-Secondary Pair Wiring Connections
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
SENSOR 1
SENSOR
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
A
U
SE
R2
COM NO
DC
USER 1
A
U
SE
R2
COM NO
DC
USER 1
COM
DUAL GATE
RADIO OPTIONS
A
B
COM OPEN +
24V
S1
COM
DUAL GATE
RADIO OPTIONS
A
B
COM OPEN +
24V
S1
Shielded cable
(3-wire)
Conduit (in the ground)
Shield wire
Note: Do not
connect the
ground shield
wire at both ends.
Ground
Primary
Secondary
99
| www.hysecurity.com
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
MX3640-01 REV. D ©2018
Содержание SwingSmart DC 20
Страница 2: ...2 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 24: ...SAFETY INFORMATION 24 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 138: ...NOTES 138 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 139: ...NOTES 139 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...