Table 12. Smart DC Controller - Installer Menu Functions
User Menu
Display
Setting Options
(Bold = Factory
Settings)
Menu Tasks and Explanations
Associated
DC Controller
Display
Connections
FO 0 (OFF)
Fire Dept Open
0 = disabled
1 = enabled
Enables Fire Department Open input.
When set to 1, signal received through
this input overrides all photoelectric
eyes and edge sensors and opens gate.
Pressing RESET button (or the OPEN
push button) is required before gate
can be closed.
+24V DC
EMERG OPEN
SE 2
IES Sensitivity
0 = maximum
sensitivity
2 = default
Setting
9 = least sensitivity
Adjusts sensitivity of internal inherent
entrapment sensor (IES). Available
settings are 0 to 9 with 9 being
least sensitive. HySecurity strongly
recommends that you avoid setting IES
sensitivity higher than 6.
NOTE:
Before changing IES sensitivity,
make sure that gate rolls smoothly
without obstruction. Fix any issues with
gate hardware.
See Note.
SS 0 (OFF)
IES STOP ONLY
0 = stop, reverse
for 2s
1 = stop only
In a Usage Class 4 environment,
operator can be set to stop gate and
not reverse gate travel after an IES
trip.
(N/A)
LC 0 (0.0 SECS)
Leaf Delay Close
0 = no delay
1 through 20 in ½
second increments
For example:
1 = ½ second
10 = 5 seconds
20 = 10 seconds
Only appears if gate operator is set up
as a Primary or a Secondary. Available
settings are 1 through 20. Each
increment adds ½ second time delay
following a command to close before
operator begins closing. Provides up
to a 10 second time delay.
DUAL GATE
inputs on both
operators
LO 0 (0.0 SECS)
Leaf Delay Open
0 = no delay
1 through 20 in ½
second increments
For example:
1 = ½ second
10 = 5 seconds
20 = 10 seconds
Only appears if gate operator is set up
as a Primary or a Secondary. Available
settings are 1 through 20. Each increment
adds ½ second time delay following a
command to open before operator
activates. Provides up to a 10 second
time delay.
DUAL GATE
inputs on both
operators
DISPLAY AND MENU OPTIONS
71
| www.hysecurity.com
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
MX3640-01 REV. D ©2018
Содержание SwingSmart DC 20
Страница 2: ...2 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 24: ...SAFETY INFORMATION 24 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 138: ...NOTES 138 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 139: ...NOTES 139 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...