POWER
WIRING AC POWER
DANGER
Turn off AC power at the source (circuit breaker
panel) before accessing the wires in the
SwingSmart DC junction box. Follow facility
Lock Out/Tag Out procedures. Make sure both
the DC and AC power switches, on the side of
the SwingSmart DC control box are in the off
position.
CAUTION
Wiring of gate operators must conform to the
NEC standards and comply with all local codes.
If you plan to connect to 208/230VAC power,
read the WARNING in the illustration below.
The voltage selector switch on the AC Power
board must be moved to the 230V position or
damage to the operator will occur and void
the Limited Warranty.
Figure 18. Wiring AC Power
Voltage selector
switch is factory
set to 115V.
If power input is 208/230V,
move the switch so 230V
appears and change the
label on the junction
box cover.
High voltage
protection cover
Service outlet
Junction box
cover and label
WARNING
DO NOT connect the
115VAC service outlet to 208 or
230VAC power supply wires! To
use the 115VAC service outlet on
a 208 or 230VAC installation, the
electrician needs to run an extra
neutral wire to the operator from
the power source and wire the
service outlet per code.
Place power switches
in OFF position.
40
| www.hysecurity.com
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
MX3640-01 REV. D ©2018
Содержание SwingSmart DC 20
Страница 2: ...2 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 24: ...SAFETY INFORMATION 24 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 138: ...NOTES 138 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...
Страница 139: ...NOTES 139 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...