Appendix B – CnC interfACe protoCol
b-22
HPR130XD Auto Gas –
806330 Revision 1
ID
Name
Description
054
HIGH SHIELD GAS PRESSURE Gas pressure is over upper limit of 7.58 bar (110 psi).
055
MV 1 INLET PRESSURE
Motor valve 1 inlet pressure is less than 3.45 bar (50 psi) or
greater than 9.65 bar (140 psi).
056
MV 2 INLET PRESSURE
Motor valve 2 inlet pressure is less than 3.45 bar (50 psi) or
greater than 9.65 bar (140 psi).
057
CUT GAS 1 PRESSURE
In the selection console, cut gas 1 outlet pressure is less than
3.45 bar (50 psi) or greater than 9.65 bar (140 psi).
058
CUT GAS 2 PRESSURE
In the selection console, if cut gas 2 outlet pressure is less than
3.45 bar (50 psi) for non-mixing, or less than 1.38 bar (20 psi)
when mixing or greater than 9.65 bar (140 psi) for non-mixing
and mixing.
060
LOW COOLANT FLOW
Coolant flow is less than the required 2.3 lpm (0.6 gpm).
061
NO PLASMA GAS TYPE
Plasma gas has not been selected.
062
NO SHIELD GAS TYPE
Shield gas has not been selected, or system is in test mode.
065 Primary
265 Secondary CHOPPER1 OVERTEMP
Chopper #1 overheated.
066 Primary
266 Secondary CHOPPER2 OVERTEMP
Chopper #2 overheated.
067 Primary
267 Secondary MAGNETICS OVERTEMP
Transformer has overheated.
071
COOLANT OVERTEMP
Torch coolant has overheated.
072
AUTOMATIC GAS CONTROL
BOARD OVERTEMP
Control board has exceeded 90° C (194° F).
073 Primary
273 Secondary CHOPPER3 OVERTEMP
Chopper #3 overheated
074 Primary
274 Secondary CHOPPER4 OVERTEMP
Chopper #4 overheated
075 Primary
275 Secondary
CURRENT TOO LOW ON LEM
#3
A current less than 10 amperes has been detected by current
sensor 3.
076 Primary
276 Secondary
CURRENT TOO LOW ON LEM
#4
A current less than 10 amperes has been detected by current
sensor 4.
093
NO COOLANT FLOW
Coolant flow is less than 0.6 gpm.
095
CURRENT TOO HIGH ON LEM
#4
Current has exceeded 35 amperes during the chopper test
099 Primary
299 Secondary CHOPPER1 OVERTEMP AT INIT Chopper #1 is indicating overtemp during power-up.
100 Primary
300 Secondary CHOPPER2 OVERTEMP AT INIT Chopper #2 is indicating overtemp during power-up.
101 Primary
301 Secondary
MAGNETICS OVERTEMP AT
INIT
Transformer is indicating overtemp during power-up.
102 Primary
302 Secondary OUTPUT CURRENT AT INIT
Chopper current signal is active on power-up.
103 Primary
303 Secondary
CURRENT TOO HIGH ON LEM
#1
A current greater than 35 amperes has been detected by current
sensor 1.
104 Primary
304 Secondary
CURRENT TOO HIGH ON LEM
#2
A current greater than 35 amperes has been detected by current
sensor 2.
105 Primary
305 Secondary
CURRENT TOO LOW ON LEM
#1
A current less than 10 amperes has been detected by current
sensor 1.
Содержание HyPerformance HPR130XD
Страница 1: ...HyPerformance Plasma HPR130XD Auto gas Instruction manual 806330 Revision 3 ...
Страница 16: ...Table of Contents viii HPR130XD Auto Gas 806330 ...
Страница 26: ...Specifications 2 2 HPR130XD Auto Gas 806330 ...
Страница 38: ...Specifications 2 14 HPR130XD Auto Gas 806330 ...
Страница 48: ...Installation 3 10 HPR130XD Auto Gas 806330 ...
Страница 51: ...Installation HPR130XD Auto Gas 806330 3 13 LHF mounting Horizontal RHF mounting Vertical RHF mounting ...
Страница 59: ...Installation HPR130XD Auto Gas 806330 3 21 1X1 J103 J300 Female Male 5 6 5 6 3X1 3X2 3X3 3X4 ...
Страница 61: ...Installation HPR130XD Auto Gas 806330 3 23 7 Caution Never use PTFE tape on any joint preparation ...
Страница 94: ...Installation 3 56 HPR130XD Auto Gas 806330 ...
Страница 101: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 7 Diagnostics screen ...
Страница 102: ...Operation 4 8 HPR130XD Auto Gas 806330 Revision 2 Test screen ...
Страница 103: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 9 Cut chart screen ...
Страница 152: ...Operation 4 58 HPR130XD Auto Gas 806330 Revision 2 ...
Страница 236: ...7 4 HPR130XD Auto Gas 806330 Discrete output functionality ...
Страница 294: ...Appendix B CNC Interface Protocol b 28 HPR130XD Auto Gas 806330 Revision 1 ...
Страница 302: ...4 HPR130XD Auto Gas 806330 ...