Appendix B – CnC interfACe protoCol
HPR130XD Auto Gas –
806330 Revision 1
b-23
ID
Name
Description
106 Primary
306 Secondary
CURRENT TOO LOW ON LEM
#2
A current less than 10 amperes has been detected by current
sensor 2.
107 Primary
307 Secondary
CURRENT TOO HIGH ON LEM
#3
A current greater than 35 amperes has been detected by current
sensor 3.
108 Primary
308 Secondary TRANSFER AT INIT
The system has detected current on the work lead during
power-up.
109
COOLANT FLOW AT INIT
Coolant flow is greater than 1.14 lpm (0.3 gpm) when pump is
off.
111
COOLANT OVERTEMP AT INIT
Coolant is indicating overtemp during power-up.
116 Primary
316 Secondary WATCHDOG INTERLOCK
CAN communication error.
123
MV 1 ERROR
Motor valve 1 did not move into position within 60 seconds.
124
MV 2 ERROR
Motor valve 2 did not move into position within 60 seconds.
133
UNKNOWN GAS CONSOLE
TYPE
The power supply control board does not recognize the gas
console installed or has not received a CAN message identifying
the type of console installed.
134 Primary
334 Secondary CHOPPER 1 OVERCURRENT
Chopper 1 current feedback has exceeded 160 amperes.
138 Primary
338 Secondary CHOPPER 2 OVERCURRENT
Chopper 2 current feedback has exceeded 160 amperes.
139
PURGE TIMEOUT ERROR
The purge cycle did not complete within 3 minutes.
140
AUTO GAS PRESSURE
TRANSDUCER #1 ERROR
Faulty transducer or auto gas control PCB
141
AUTO GAS PRESSURE
TRANSDUCER #2 ERROR
Faulty transducer or auto gas control PCB
142
AUTO GAS PRESSURE
TRANSDUCER #3 ERROR
Faulty transducer or auto gas control PCB
143
AUTO GAS PRESSURE
TRANSDUCER #4 ERROR
Faulty transducer or auto gas control PCB
144
MANUAL GAS CONSOLE
INTERNAL FLASH MEMORY
ERROR
Replace manual gas console control PCB
145
AUTOMATIC GAS CONSOLE
INTERNAL FLASH MEMORY
ERROR
Replace auto gas console control PCB
146 Primary
346 Secondary
CHOPPER #3 OVERTEMP AT
INIT
Chopper #3 is indicating over temp during power-up
147 Primary
347 Secondary
CHOPPER #4 OVERTEMP AT
INIT
Chopper #4 is indicating over temp during power-up
151 Primary
351 Secondary SOFTWARE FAIL
Software has detected an incorrect state or condition.
152
INTERNAL FLASH ERROR
DSP memory is not working properly.
153
PS EEPROM ERROR
EEPROM memory on power supply board not working.
154 Primary
354 Secondary CHOPPER 3 OVER CURRENT
Chopper 3 current feedback has exceeded 160 amperes
155 Primary
355 Secondary CHOPPER 4 OVER CURRENT
Chopper 4 current feedback has exceeded 160 amperes
Содержание HyPerformance HPR130XD
Страница 1: ...HyPerformance Plasma HPR130XD Auto gas Instruction manual 806330 Revision 3 ...
Страница 16: ...Table of Contents viii HPR130XD Auto Gas 806330 ...
Страница 26: ...Specifications 2 2 HPR130XD Auto Gas 806330 ...
Страница 38: ...Specifications 2 14 HPR130XD Auto Gas 806330 ...
Страница 48: ...Installation 3 10 HPR130XD Auto Gas 806330 ...
Страница 51: ...Installation HPR130XD Auto Gas 806330 3 13 LHF mounting Horizontal RHF mounting Vertical RHF mounting ...
Страница 59: ...Installation HPR130XD Auto Gas 806330 3 21 1X1 J103 J300 Female Male 5 6 5 6 3X1 3X2 3X3 3X4 ...
Страница 61: ...Installation HPR130XD Auto Gas 806330 3 23 7 Caution Never use PTFE tape on any joint preparation ...
Страница 94: ...Installation 3 56 HPR130XD Auto Gas 806330 ...
Страница 101: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 7 Diagnostics screen ...
Страница 102: ...Operation 4 8 HPR130XD Auto Gas 806330 Revision 2 Test screen ...
Страница 103: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 9 Cut chart screen ...
Страница 152: ...Operation 4 58 HPR130XD Auto Gas 806330 Revision 2 ...
Страница 236: ...7 4 HPR130XD Auto Gas 806330 Discrete output functionality ...
Страница 294: ...Appendix B CNC Interface Protocol b 28 HPR130XD Auto Gas 806330 Revision 1 ...
Страница 302: ...4 HPR130XD Auto Gas 806330 ...