Maintenance
HPR130XD Auto Gas –
806330
5-37
coolant flow tests
If the CNC screen shows a coolant flow error (093 or 060), turn OFF the system and then ON again to clear the error.
Then perform the following tests to find the cause of the problem.
An in-line flow meter is the most accurate way to measure the flow rate, but can not be used with all the tests described
without custom fittings. An in-line flow meter (part number 128933) is available from Hypertherm. The following “bucket”
tests give a good idea of the flow rate.
Note: The CNC screens shown here are for reference. The screens you work with may look different, but should
have the same functions shown here.
before testing
Note: Coolant must be drained from the system before the filter/strainer is cleaned (step 1 below). The coolant in
the system will drain out as soon as the filter/strainer is removed.
1. Clean the filter/strainer.
2. Replace the filter on the rear of the power supply.
3. Verify that the system has the correct level of coolant, when refilling the system after completing steps 1 and 2.
Using the Hypertherm flow meter (128933)
Use the steps below to get an accurate reading from the flow meter.
1. Hold the flow meter upright. Square in both axis.
2. Take your reading from the edge shown below.
Nut
Filter/Strainer
HPR130 pump filter/strainer
2.0
1.8
1.6
1.4
1.2
1.0
.8
.6
.4
.2
1.2
1.0
Flow
direction
Float
Read from this edge
Example shown 1.1
Filter on the rear of the
power supply
Содержание HyPerformance HPR130XD
Страница 1: ...HyPerformance Plasma HPR130XD Auto gas Instruction manual 806330 Revision 3 ...
Страница 16: ...Table of Contents viii HPR130XD Auto Gas 806330 ...
Страница 26: ...Specifications 2 2 HPR130XD Auto Gas 806330 ...
Страница 38: ...Specifications 2 14 HPR130XD Auto Gas 806330 ...
Страница 48: ...Installation 3 10 HPR130XD Auto Gas 806330 ...
Страница 51: ...Installation HPR130XD Auto Gas 806330 3 13 LHF mounting Horizontal RHF mounting Vertical RHF mounting ...
Страница 59: ...Installation HPR130XD Auto Gas 806330 3 21 1X1 J103 J300 Female Male 5 6 5 6 3X1 3X2 3X3 3X4 ...
Страница 61: ...Installation HPR130XD Auto Gas 806330 3 23 7 Caution Never use PTFE tape on any joint preparation ...
Страница 94: ...Installation 3 56 HPR130XD Auto Gas 806330 ...
Страница 101: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 7 Diagnostics screen ...
Страница 102: ...Operation 4 8 HPR130XD Auto Gas 806330 Revision 2 Test screen ...
Страница 103: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 9 Cut chart screen ...
Страница 152: ...Operation 4 58 HPR130XD Auto Gas 806330 Revision 2 ...
Страница 236: ...7 4 HPR130XD Auto Gas 806330 Discrete output functionality ...
Страница 294: ...Appendix B CNC Interface Protocol b 28 HPR130XD Auto Gas 806330 Revision 1 ...
Страница 302: ...4 HPR130XD Auto Gas 806330 ...