Maintenance
HPR130XD Auto Gas –
806330
5-39
test 1 – return line
Note: An in-line flow meter is required to complete this test.
1. Turn OFF the power. Remove the return coolant line (blue hose with red tape),
and connect the flow meter to measure the flow rate.
2. Measure the flow rate on the flow meter. Turn ON the power. Turn ON the
pump manually using the manual pump control button on your CNC screen
(see step 1 under “Manual pump operation”). Write down the flow rate from
the flow meter.
3. Reconnect the return coolant line (blue hose with red tape).
If the flow rate is 0.8 gpm or more, go to test 7.
If the flow rate is less than 0.8 gpm, go to test 2.
If there is no flow, go to pump and motor troubleshooting.
test 2 – supply line at ignition console
Note: Remove the torch-lead coolant hoses to acess the supply line.
1. Turn OFF the power. Remove the supply coolant line (blue hose with
green tape) from the RHF/LHF console, and place it in a 3.8 liter
(1 gallon) container. A Hypertherm coolant container works well.
2. Measure how long it takes to fill the container. Turn ON the power.
Turn ON the pump manually using the manual pump control button
on your CNC screen (see step 1 under “Manual pump operation”).
Write down how long it takes to fill the container.
3. Reconnect the coolant lines.
If the container is full in 65 seconds or less, go to test 3.
If it takes more than 65 seconds to fill the container, go to test 6.
Torch-lead
coolant hoses
Содержание HyPerformance HPR130XD
Страница 1: ...HyPerformance Plasma HPR130XD Auto gas Instruction manual 806330 Revision 3 ...
Страница 16: ...Table of Contents viii HPR130XD Auto Gas 806330 ...
Страница 26: ...Specifications 2 2 HPR130XD Auto Gas 806330 ...
Страница 38: ...Specifications 2 14 HPR130XD Auto Gas 806330 ...
Страница 48: ...Installation 3 10 HPR130XD Auto Gas 806330 ...
Страница 51: ...Installation HPR130XD Auto Gas 806330 3 13 LHF mounting Horizontal RHF mounting Vertical RHF mounting ...
Страница 59: ...Installation HPR130XD Auto Gas 806330 3 21 1X1 J103 J300 Female Male 5 6 5 6 3X1 3X2 3X3 3X4 ...
Страница 61: ...Installation HPR130XD Auto Gas 806330 3 23 7 Caution Never use PTFE tape on any joint preparation ...
Страница 94: ...Installation 3 56 HPR130XD Auto Gas 806330 ...
Страница 101: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 7 Diagnostics screen ...
Страница 102: ...Operation 4 8 HPR130XD Auto Gas 806330 Revision 2 Test screen ...
Страница 103: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 9 Cut chart screen ...
Страница 152: ...Operation 4 58 HPR130XD Auto Gas 806330 Revision 2 ...
Страница 236: ...7 4 HPR130XD Auto Gas 806330 Discrete output functionality ...
Страница 294: ...Appendix B CNC Interface Protocol b 28 HPR130XD Auto Gas 806330 Revision 1 ...
Страница 302: ...4 HPR130XD Auto Gas 806330 ...