INSPECTION
CHARGING OUTPUT CHECK
Start the engine and keep it running at 5,000 rpm.
Using the pocket tester, m e a s u r e the DC volt-
age between the battery terminal
and .
If the tester reads under 13.5V or over 15.0 V, check
the magneto no-load performance and regulator /
rectifier.
MAGNETO NO-LOAD PERFORMANCE
Disconnect the three lead wires from the magneto
terminal.
Start the engine and keep it running at 5,000 rpm.
Using the pocket tester, measure the AC volt-
age between the three lead wires.
If the tester reads under 70 V the magneto is faulty.
13.5 15.0V (at 5,000 rpm)
Standard charge
Regulator
Rectifier
DCV
Battery
IG. switch
Pocket tester : 09900-25002
CAUTION
When making this test, be sure that the battery is
full-charged condition.
6-9 ELECTRICAL SYSTEM
Over 70 V (at 5,000 rpm)
Standard NO-load perfor-
mance of magneto