7 Gas system
106
B-MC - 12/18-2 - EHG-0016-01EN
The DuoControl regulating system can be heated (defroster). If winter oper-
ation is set at the operating unit, the DuoControl regulating system will be
heated automatically. Thus, faults of the gas system due to frost in winter
are prevented.
1
Yellow indicator lamp, defroster
2
Winter operation position
3 OFF
position
4
Summer operation position
5
Red indicator lamp, primary bottle
empty
6
Green indicator lamp, supply from
primary bottle
7 Rocker
switch
Fig. 124 Operating unit (DuoControl)
At the operating unit (Fig. 124), the gas supply via the DuoControl regulating
system is switched on and off. The regulator taps (Fig. 122,2) of the gas bot-
tles and the gas isolator taps of the devices must be opened manually.
Summer and winter operation are switched with the rocker switch
(Fig. 124,7) on the operating unit.
The two indicator lamps on the operating unit indicate the level of the pri-
mary bottle. When the green indicator lamp (Fig. 124,6) is lit, the primary
bottle is sufficiently filled. When the red indicator lamp (Fig. 124,5) illumi-
nates, the primary bottle is empty. In this case, the reserve bottle is used for
the gas supply.
Connect the gas bottles.
Use the knob (Fig. 123,1) on the reversing valve to select the gas bottle
which is to be the primary source of gas (primary bottle). Always turn the
knob as far as it will go.
Open regulator taps (Fig. 122,2) on the gas bottles.
Press the green button of the hose break guard (Fig. 122,1). The green
marking is shown in the inspection window (Fig. 123,2).
Switch on the DuoControl regulating system at the operating unit
(Fig. 124). To do so, set the rocker switch (Fig. 124,7) to winter opera-
tion (Fig. 124,2) or to summer operation (Fig. 124,4). The yellow de-
froster indicator lamp (Fig. 124,1) is lit when winter operation is selected.
Set the rocker switch (Fig. 124,7) to the OFF position (Fig. 124,3). The
indicator lamps go out.
Close regulator taps (Fig. 122,2) on the gas bottles.
When changing gas bottles, do not smoke or create any open fire.
When you have changed the gas bottle, check whether gas escapes
at the connection points and unions. Use a leakage search spray to
spray the relevant connection point or union. These agents are
available at the accessories shop.
Defroster
Operating unit
Putting into operation:
Switching on
summer/winter operation:
Switching off:
Changing gas bottles
Содержание BMC 550
Страница 2: ...Instruction manual 2 B MC 12 18 2 EHG 0016 01EN...
Страница 8: ...Checklist before first journey of the vehicle 8 B MC 12 18 2 EHG 0016 01EN...
Страница 12: ...1 Introduction 12 B MC 12 18 2 EHG 0016 01EN...
Страница 20: ...2 Safety 20 B MC 12 18 2 EHG 0016 01EN...
Страница 54: ...4 During the journey 54 B MC 12 18 2 EHG 0016 01EN...
Страница 140: ...8 Electrical system 140 B MC 12 18 2 EHG 0016 01EN...
Страница 172: ...9 Appliances 172 B MC 12 18 2 EHG 0016 01EN...
Страница 186: ...10 Sanitary fittings 186 B MC 12 18 2 EHG 0016 01EN...
Страница 202: ...11 Care 202 B MC 12 18 2 EHG 0016 01EN...
Страница 224: ...13 Wheels and tyres 224 B MC 12 18 2 EHG 0016 01EN...
Страница 240: ...16 Technical data 240 B MC 12 18 2 EHG 0016 01EN...
Страница 242: ...17 Instructions for the service partner 242 B MC 12 18 2 EHG 0016 01EN...
Страница 252: ...Index 252 B MC 12 18 2 EHG 0016 01EN...